Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)
Cooling Method: Water-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: Applicable to Deionized Water Piping
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
. 9-2 9.1.3 HRS090-A-46. 9-3 9.1.4 HRS090-W-20. 9-4 9.1.5 HRS090-W-40. 9-5 9.1.6 HRS090-W-46. 9-6 9.1.7 Refrigerant with GWP reference . 9-7 9.1.8 Communication specification . 9-7 9.2 Outline dimensions . 9-8 9.2.1 HRS090-A-20/40/46-. 9-8 9.2.2 HRS090-W-20/40/46-. 9-9 9.3 Flow diagram . 9-10 9.3.1 HRS090-A-20/40/46-. 9-10 9.3.2 HRS090-W-20/40/46 . 9-10 9.4 Cooling capacity . 9-11 9.4.1 HRS090
Cardboard box Forklift insertion side 800 mm or more 800 mm or more 100 mm or more Less than 150 mm Wooden skid Less than 150 mm Forklift insertion side
40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)
Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) Specications Model HRSH090-Al-20-l HRSH090-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) (GWP1975) Refrigerant charge kg 1.32 Control method PID control Ambient temperature/humidity Note 1), 9) C/% 5 to 45/30 to 70% Circulating uid Note 2) Tap water, 15% Ethylene
VM SUP blocking disk assembly SY30M-40-2A SY50M-40-1A SY70M-40-1A EXH blocking disk assembly Series SY3000 SY5000 SY7000 SY30M-40-1A SY50M-40-1A SY70M-40-1A XT34 Label for blocking disk If the blocking disk assembly is ordered using the manifold specification sheet and ordered at the same time as the manifold, the position where the blocking disk assembly is inserted will be labeled and
type 0.1 5 to 40 V V V HRS090 Standard type 0.5 5 to 35 V Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V HRSH090 Inverter type 0.1 5 to 40 V Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (400 V as standard, 200 V as an option
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz)
Cooling Method: Water-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: -
Nil Rc F G (with Rc-G conversion fitting) N NPT (with Rc-NPT conversion fitting) Power supply 40 3-phase 380 to 415 VAC (50/60 Hz) Specifications Model HRSH100-Al-40-l HRSH150-Al-40-l HRSH200-Al-40-l HRSH250-Al-40-l HRSH300-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.27 2.1 2.1 2.8 2.8 Control method PID control Ambient temperature/Altitude
Pump Capacity HRS100/150-Am-20/40-m HRS100/150-Wm-20/40-m 0.5 50 Circulating fluid pressure [MPa] HRS Circulating fluid outlet (60 Hz) Usable range (50 Hz) 0.4 40 HRS 090 Pump head [m] 0.3 30 Usable range (60 Hz) HRS 100/150 HRS 100/150 Circulating fluid outlet (50 Hz) 0.2 20 HRSH 090 Circulating fluid return port 0.1 10 HRSH 0 0 0 10 20 30 40 50 60 70 HRSE Circulating fluid flow rate [L
Description Size 1 Valve Rc1/2 2 Valve Rc3/4 3 Y-strainer (#40) (Accessory) Rc3/4 4 Flow meter Prepare a ow meter with an appropriate ow range. 5 Valve (Part of thermo-chiller) Rc1/4 6 Y-strainer (#40) Rc1/2 7 Pressure gauge 0 to 145 psi (0 to 1 MPa) 8 Y-strainer (#40) or lter Rc3/4 Cable Specications Power supply and signal cable should be prepared by user.
Applicable model HRS-WL003 HRS090-mm-20/40 Parts List q No.