SMC Corporation of America
Elite Part Number Search
Search Results "HRSH090-AN-20-B"

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: BJM (w/ Earth Leakage Breaker + w/ Automatic Fluid Fill Function + Applicable to Deionized Water Piping)

Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: w/ Earth Leakage Breaker + w/ Automatic Fluid Fill Function + Applicable to Deionized Water Piping

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

2 VA (AC), 2 W (DC) Operating voltage: AC, DC 100 V or less Model A B C D Applicable model IS10M-20-A 10.6 74.2 64.4 28 AC20l-B IS10M-30-A 12.6 84.5 70.5 30 AC25l-B, AC30l-B IS10M-40-A 14.6 93.3 75.3 36 AC40l-B IS10M-50-A 16.6 97.3 77.3 44 AC40l-06-B IS10M-60-A 22 92.5 68.5 53 AC50l-B, AC55l-B, AC60l-B Maximum operating current 12 V to 24 VAC, DC: 50 mA 48 VAC, DC: 40 mA 100 VAC, DC: 20

Note 2) 400 V type is provided with an earth leakage breaker -B as standard.

Cooling Capacity HRL100-Am-20 (CH1)1 HRL200-Am-20 (CH1)1 14 30 12 Technical Data HRS-R HRS HRS090 HRS 100/150 HRS200 HRSH090 HRSH HRSE HRR HRL HRZ HRZD HRW HECR HEC HED HEB 25 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 20 8 15 6 10 Ambient temperature 45C 4 Ambient temperature 45C 5 2 0 0 15 20 25 15 20 25 Circulating fluid temperature [

Thermo-chiller Air-cooled 200 V/400 V Type Inverter Type (400 V type only) (Option S only) (UL Standards) (Option S only) RoHS HRSH090 Series How to Order A HRSH090 20 Cooling capacity 090 9.5 kW Option Nil None B Note 1) With earth leakage breaker J With automatic uid ll function M Applicable to deionized water piping S Note 2) Conforming to CE/UL standards Cooling method A Air-cooled refrigeration

(Pitch) P = 17.5 50 XT34 4(A) port side : Blue (For rubber seal) : Gray (For metal seal) 2(B) port side : Yellow DIN rail bracket mounting screw (For DIN rail mounting) (Light/surge voltage suppressor) 20.5 19.6 DIN rail A B A B A 14 A B A 14 A B A 14 A B A 14 A 14 PE 1P 3EB X 5EA 106.2 5.5 24.6 23.2 116.6 35 96.2 20 20 81.6 74.1 30.2 20 43.8 40.2 8 12 B 12 B 12 B 12 B 12 B 4 x 4.5 (For mounting

Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.

Applicable model Rated current [A] Sensitivity of leak current [mA] Short circuit display method HRSH100--20-B 30 Earth leakage breaker HRSH150--20-B HRSH200--20-B 40 HRSH250--20-B 50 HRSH300--20-B 30 Mechanical button * 400 V type is equipped as standard.

This information is needed when contacting an SMC sales distributor. An example of HRS090-A-20 "3~" stands for "3 interphase".

HRS 100/150 HRS 100/150 Applicable model Dimension [mm] A B C HRS100/150-A-20/40-A 830 302 1552 HRS100/150-W-20/40-A 570 401 1353 C HRSH 090 HRSH 118 HRSE A B Option symbol With Earth Leakage Breaker B HRZ HRZD HRS 20 B With earth leakage breaker HRW A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.

Applicable model Dimension in [mm] A B C HRS100/150-A-20/40-A 32.7 [830] 11.9 [302] 61.1 [1552] HRS100/150-W-20/40-A 22.4 [570] 15.8 [401] 53.5 [1353] C 118 A B Option symbol With Earth Leakage Breaker B HRS 20 B With earth leakage breaker A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.

Note 2) 400 V type is provided with an earth leakage breaker -B as standard.