Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: Rc, Option: w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: Rc, Option: w/Caster Adjuster-foot
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150-W-20/40/46. 8-13 8.5 Pump capacity . 8-14 8.5.1 HRS100/150-A/W-20/40/46. 8-14 8.6 Types of Hazard Labels (HRS--40/46-) . 8-15 8.6.1 Positions of danger warning label . 8-16 8.7 Standards . 8-17 8.8 Sample DoC.
[C] HRS100-W-20/40(60 Hz) HRS100-W-20/40(50 Hz) 14 14 Facility water temperature 32C 12 12 Cooling capacity [kW] Cooling capacity [kW] Facility water temperature 32C 10 10 8 8 6 6 4 4 Facility water temperature 40C Facility water temperature 40C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRS150-A-20/40(50 Hz) HRS150-
) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.
x Width 925 x Depth 955] HRS150-W -20-A 459 [208] HRS150-A-20
, IDF6E-20 IDF8E-20, IDF11E-20 5 A IDU3E-20, IDU4E-20 IDU6E-20, IDU8E-20, IDU11E-20 [mm] Dimensions Model A B C D E F IDF22E-20 59 40 IDF15E1-20, IDF22E-20, IDF37E-20 IDU15E1-20 IDF22E-30, IDF37E-30 IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 25 46 IDF37E-20 IDF22E-30 39 30 mA 125 10 A 60 60 IDF37E-30 IDF55E-30 148 81 50 36 IDF75E-30 133 73 IDU22E-30 151 74 200 V type IDF75E-30, IDU75E-30 15
Specications Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Model HRS100-Al-20-l HRS150-Al-20-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.3 1.65 Control method PID control Ambient temperature Note 1) C 5 to 45 Circulating uid Note 2) Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range
-A/W-#-40, CHILLER, 729, 33 lb
Note 3) This is the default setting of the HRS150.
The operating settings can be changed by the user. The default setting for alarm code “AL09” is continued operation for the HRS012 to 060.
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: W (SI Unit Only)