Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: K (w/Fluid Fill Port, Manual)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: AK (w/Caster Adjuster-foot and Fluid Fill Port)
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Fluid Fill Port, Manual
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Caster Adjuster-foot
Cooling Capacity: 15 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Caster Adjuster-foot and Fluid Fill Port
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
This information is needed when contacting an SMC sales distributor. An example of HRS150-A-20 "3~" stands for "3 interphase".
(C) Correction factor 1.25 1.11 1 0.90 0.63 2 to 25 30 32 35 40 2 to 25 30 32 35 40 45 2 to 25 30 32 35 40 2 to 25 30 32 35 40 2 to 25 30 32 35 40 Note) For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45C.
415 VAC (50/60 Hz) 20 A M5 4 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 HRS150-Al-40-l HRS150-Wl-40-l Note) An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600 V, are used at an ambient temperature of 30C.
) Ambient temperature 104F (40C) 10 10 8 8 Ambient temperature 113F (45C) Ambient temperature 113F (45C) 6 6 4 4 2 2 0 0 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] Circulating fluid temperature F [C] Circulating fluid temperature F [C] HRS150-W -20/40(50 Hz) HRS150-W -20/40(60 Hz) 20 20 Facility water temperature 90F (32C)
VM SUP blocking disk assembly SY30M-40-2A SY50M-40-1A SY70M-40-1A EXH blocking disk assembly Series SY3000 SY5000 SY7000 SY30M-40-1A SY50M-40-1A SY70M-40-1A XT34 Label for blocking disk If the blocking disk assembly is ordered using the manifold specification sheet and ordered at the same time as the manifold, the position where the blocking disk assembly is inserted will be labeled and
[C] Correction factor 2 to 25 1.25 30 1.11 32 1 35 0.90 40 0.63 *1 For the water-cooled type, the correction factor is determined to 1 in an ambient temperature range of 2 to 45C.
-A/W-#-40, CHILLER, 729, 33 lb