SMC Corporation of America
Elite Part Number Search
Search Results "HRS150-A-46-A"

/150-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150-W-20/40/46. 8-13 8.5 Pump capacity . 8-14 8.5.1 HRS100/150-A/W-20/40/46. 8-14 8.6 Types of Hazard Labels (HRS--40/46-) . 8-15 8.6.1 Positions of danger warning label . 8-16 8.7 Standards . 8-17 8.8 Sample DoC

l03-A 3/8 Y510-l02-A 1/4 18.6 66 46 44 24 AC40-06-A, AC40B-06-A AC40C-06-A Y510-l03-A 3/8 Caution on Mounting If a T-spacer is used on the inlet side of the lubricator, lubricant may be mixed.

x Width 925 x Depth 955] HRS150-W -20-A 459 [208] HRS150-A-20 A> 4.

Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm

type IDF75E-30, IDU75E-30 15 A IDF100F 30 A IDF125F IDF150F IDF190D 50 A IDF240D IDF370D 60 60 50 46 IDU37E-30 146 122 IDU55E-30 148 55 36 IDU75E-30 166 73 70 IDF100F to 150F Dimensions [mm] A Model A B IDF100F 434 535 IDF125F 448 IDF150F 628 537 B 31 Options IDF/IDU Series Power supply terminal block connection S T Option symbol Option symbol IDF1E-10 to 15E1-10, IDU3E-10 to 15E1-10 With

Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: -, UL Certification: -, Option 2: -

1485 x Width 925 x Depth 955 HRS150-Wl-l 189 HRS100-Al-l-A 231 Height 1710 x Width 1185 x Depth 955 HRS150-Al-l-A 237 HRS100-Wl-l-A 205 Height 1610 x Width 925 x Depth 955 HRS150-Wl-l-A 208 IDH Forklift insertion side HRS150-A-20 A> 4.

Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A (w/Caster Adjuster-foot)

Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: K (w/Fluid Fill Port)

Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Caster Adjuster-foot, UL Certification: -, Option 2: -

Cooling Capacity: 150, Thread Type: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -

Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460-480 VAC (60 Hz)], Option: w/Caster Adjuster-foot

Thermo-chiller Air-cooled 200 V Type Standard Type HRS100/150 Series RoHS How to Order 100 A 20 HRS Option Cooling capacity 100 10 kW 150 15 kW Cooling method Nil None A With caster adjuster-foot B With earth leakage breaker B1 With earth leakage breaker with handle K Note) With uid ll port A Air-cooled refrigeration Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT

A large digital display provides a clear view of the current and set values. 

If a bypass piping set has already been installed and there is a valve, close the valve according to the situation to increase the discharge pressure of the circulating fluid.
③ Check whether the pump operates and the discharge pressure rises to determine if the flow rate is low or not present at all.

Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Capacity: 150, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: -, UL Certification: -, Option 2: -