SMC Corporation of America
Elite Part Number Search
Search Results "HRS100-WN-20-ABK"

/150-A-20. 8-1 8.1.2 HRS100/150-A-40. 8-2 8.1.3 HRS100/150-A-46. 8-3 8.1.4 HRS100/150-W-20. 8-4 8.1.5 HRS100/150-W-40. 8-5 8.1.6 HRS100/150-W-46. 8-6 8.1.7 Refrigerant with GWP reference . 8-7 8.1.8 Communication specification . 8-7 8.2 Outline dimensions . 8-8 8.2.1 HRS100/150-A-20/40/46. 8-8 8.2.2 HRS100/150-W-20/40/46. 8-9 8.3 Flow diagram . 8-10 8.3.1 HRS100/150-A-20/40/46. 8-10 8.3.2

/300-A-40. 8-9 8.2.4 HRSH100/150/200/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250

Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)

Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)

Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Option: w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port

Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port

) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.

Cable size Crimped terminal on the rated current thermo-chiller side HRS100-Al-20-l HRS100-Wl-20-l 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 4 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 30 A M5 HRS150-Al-20-l HRS150-Wl-20-l 40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-Al-40-l HRS100-Wl-40-l 3-phase 380 to

37.6 [Height 1585 x Width 1185 x Depth 955] HRS150-A -20 481 [218] HRS100-W -20 410 [186] Height 58.5 x Width 36.4 x Depth 37.6 [Height 1485 x Width 925 x Depth 955] HRS150-W -20 417 [189] HRS100-A -20-A 509 [231] Height 67.3 x Width 46.7 x Depth 37.6 [Height 1710 x Width 1185 x Depth 955] HRS150-A -20-A 522 [237] HRS100-W -20-A 452 [205] Height 63.4 x Width 36.4 x Depth 37.6 [Height 1610

Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)]

Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: -

Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)