SMC Corporation of America
Elite Part Number Search
Search Results "HRS100-AN-46-AK"

Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: AK (A + K), UL Certification: None, Option 2: W (SI Unit Only)

Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: None, Option 2: SI Unit Only

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

Install an air filter. Install an air filter at the upstream side of valve. Select an air filter with a filtration degree of 5 m or finer. Maintenance 2. Install an aftercooler, air dryer or water droplet separator, etc. Compressed air that contains a large amount of drainage can cause malfunction of pneumatic equipment.

. 8-7 8.1.8 Communication specification . 8-7 8.2 Outline dimensions . 8-8 8.2.1 HRS100/150-A-20/40/46. 8-8 8.2.2 HRS100/150-W-20/40/46. 8-9 8.3 Flow diagram . 8-10 8.3.1 HRS100/150-A-20/40/46. 8-10 8.3.2 HRS100/150-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150

Select the proper size of cable according to an actual condition.

Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.

Do not use these values for the thermal set values, etc. *7 Product other than the Option R is not equipped with an earth leakage breaker. Purchase an appropriate earth leakage breaker separately.

HRSH Series 7.4 Operation Stop for an Extended Period of Time 7-9 HRX-OM-Q026 Chapter 7 Control, Inspection and Cleaning 7.4 Operation Stop for an Extended Period of Time HRSH Series 7-10 HRX-OM-Q026 Chapter 8 Documents Chapter 8 Documents 8.1 Specifications 8.1.1 HRSH100/150/200/250/300-A-20Table 8-1 Specifications of HRS100/150/200/250/300-A-20Model HRSH100-A HRSH150-A HRSH200-A HRSH250

Retainer prevents an accidental loss of needle.

46 119.2 58 136 173 MORE DIMENSIONS S E E N E X T P A G E Courtesy of Steven Engineering, Inc. !

M N 4-O T Q 2-P AH AG S K W U L B AL I 4-AK hole R AA AP J X AB A Y + Stroke V AI Z + Stroke AJ For 4-AO AG AN AI Cutout window 100 piston rod end connection AM Mounting dimensions For standard strokes (mm) Bore size (mm) Stroke range (mm) O N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA P A 75, 100 125, 150 200, 250 300 63 80 100 M12 x 1.75 depth 23 100 66 180 135 117 65 228 60 M12 234

T 2 x P (Rc, NPT, G) Q AH AG S U W K L B R A AL I J AI AJ AP 4 x AK hole AA AB V Y + Stroke X Z + Stroke For 4 x AO AG AN AI Cutout window AM Mounting dimensions (mm) Bore size (mm) 20 25 32 40 50 Stroke range (mm) AA AB AG AH AI AJ AK AL AM AN AO AP B I J K L M N O A 11 11 112 125 82 95 6.6 9 65 115 M6 25 108 30 55 60 80 25 45 M6 x 1 depth 9 90 75, 100, 125, 150, 200 14 13 134 150 92 108

hole Rc 1/4 unlocking port Unlocked when pressurized Rc1/8 BC Element AL I AP GC GD J V R Q AI A AA AB AJ X Y + Stroke Z + Stroke AG 4 x AO AN AI AM Cutout window 100 piston rod end connection Mounting dimensions Standard Stroke (mm) Bore size (mm) Stroke range (mm) A AA AB AG AH AI AJ AK AL AM AN AO AP B GC GD GL GL1 GR I J K L M N 50 63 80 100 200 25 25 228 250 158 180 14 12 135 234 M12

14.2 22 (22) AS231F-02-10(S)A 10 15.9 20.9 38.1 (38.2) 24.7 47.3 15.6 23 (24) AS331F-02-06(S)A 6 8.2 16.5 29.9 (30) 17.5 40.1 AQ 1/4 17 (17.5) 12.9 13 ASV 13.3 42 (42) AS331F-02-08(S)A 8 13.2 37.1 23.5 59.9 14.2 43 (43) AS331F-02-10(S)A 10 15.9 17.4 23 41.2 26.1 62.5 15.6 46 (46) AS331F-02-12(S)A 12 18.5 42.5 28.3 64.7 17 48 (48) AS331F-03-06(S)A 6 11.2 12.9 16.6 20.2 36 21.4 57.8 AK 1/4