Search Results "HRS100-AN-40-A"

Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: AK (w/Caster Adjuster-foot and Fluid Fill Port)

Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: w/Caster Adjuster-foot and Fluid Fill Port

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

AFD20-A) and NPT1/4 (applicable to the AFM30-A/40-A, AFD30-A/40-A).

. 8-7 8.1.8 Communication specification . 8-7 8.2 Outline dimensions . 8-8 8.2.1 HRS100/150-A-20/40/46. 8-8 8.2.2 HRS100/150-W-20/40/46. 8-9 8.3 Flow diagram . 8-10 8.3.1 HRS100/150-A-20/40/46. 8-10 8.3.2 HRS100/150-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150

Cable size Crimped terminal on the rated current thermo-chiller side HRS100-Al-20-l HRS100-Wl-20-l 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 4 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 30 A M5 HRS150-Al-20-l HRS150-Wl-20-l 40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-Al-40-l HRS100-Wl-40-l 3-phase 380 to

Applicable model Dimension in [mm] A B C HRS100/150-A-20/40-A 32.7 [830] 11.9 [302] 61.1 [1552] HRS100/150-W-20/40-A 22.4 [570] 15.8 [401] 53.5 [1353] C 118 A B Option symbol With Earth Leakage Breaker B HRS 20 B With earth leakage breaker A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.

OFF 45 ON Max. 6 38 24.5 Symbol 3 port (A) 2 (A) 2 1.5 3 1.5 28 82 (110) 12 12 1 (P) R port (5 port only) 5 port (A) 2 (A) 2 12 12 1 (P) 3 (R) 3 (R) 32 16 40 R port (5 port only) 3 x 1/4 53.2 25 25 * 0.5 MPa supply 63.5 F.O.F.* 40 N T.T. 45 Foot pedal VM220-02-40A VM230-02-40A 3 x 6.5 mounting hole Symbol 2 port 54 71 (A) 2 152 12 10 159 1 (P) 177 3 port (A) 2 1/4 2(A) T.T. 12 10 1 (P) 3

A voltage drop may cause the air dryer to stop operating. *1 Select an earth leakage breaker with a sensitivity of leak current of 30 mA and a rated current of 10 A. <200 VAC> Connect the power supply to the terminal block. Install an earth leakage breaker*2 suitable to each model for the power supply.

HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250-W-20/40. 8-17 8.5 Pump Capacity . 8-18 8.5.1 HRSH100-A-20/40-, HRSH100-W-20/40. 8-18 8.5.2 HRSH150/200-A-20/40-HRSH150/200/250-W-20/40. 8-18 8.5.3 HRSH250/300

40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example

40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)

Description Size 1 Valve Rc1/2 2 Valve Rc1 3 Y-strainer (#40) (Accessory)* Rc1 4 Flow meter Prepare a flow meter with an appropriate flow range. 5 Valve (Part of thermo-chiller) Rc1/4 6 Pressure gauge 0 to 1 MPa 7 Y-strainer (#40) or filter Rc1/2 8 Valve Rc3/8 9 Y-strainer (#40) or filter Rc3/8 * If foreign objects of 20 m or larger may enter, install a particle filter separately.

type 0.1 5 to 40 V V V HRS090 Standard type 0.5 5 to 35 V Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V HRSH090 Inverter type 0.1 5 to 40 V Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (400 V as standard, 200 V as an option

as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 73 Circulating Fluid Temperature Controller

14 A Current consumption 5 A (100 V) to 2.5 A (240 V) 9 A (100 V) to 4 A (240 V) 10 A (100 V) to 4 A (240 V) 8 A (200 V) Power consumption 440 W*1 850 W*1 900 W*2 1500 W*2 Alarm Refer to Alarm.