SMC Corporation of America
Elite Part Number Search
Search Results "HRS090-WN-46"

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: J (w/Automatic Fluid Fill Function)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: M (Applicable to Deionized Water Piping)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: W (SI Unit Only)

Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: w/Automatic Fluid Fill Function

Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: Applicable to Deionized Water Piping

Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: SI Unit Only

the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, WATER COOLED, HRS090

the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, WATER COOLED, HRS090

the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, WATER COOLED, HRS090

HRS090 Series 4.10 Register Map 4-17 HRX-OM-T004 Chapter 4 MODBUS communication function 4.10.5 Status flag The status of the product is read by the following assignment.

M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.

Wn X-axis Xn Y-axis Yn Z-axis Zn Z X Wa 65 mm 0 mm 0.88 kg 5 mm 111 Wb 150 mm 0 mm 4.35 kg 42.5 mm 210 Y Y Wc 150 mm 111 mm 0.795 kg 42.5 mm Wd 150 mm 210 mm 0.5 kg 42.5 mm n = a, b, c, d 3.

Wn Y-axis Yn Z-axis Zn X-axis Xn Z X Wa 0 mm 5 mm 0.88 kg 65 mm 111 Wb 0 mm 42.5 mm 4.35 kg 150 mm 210 Y Y Wc 111 mm 42.5 mm 0.795 kg 150 mm Wd 210 mm 42.5 mm 0.5 kg 150 mm n = a, b, c, d 3.

(variation on the order of 30%) Large variations may occur depending on the surrounding environment. 6, 10, 15, 20 (mm) Auto switch model A B D-M9 D-F9W C D-M9 D-F9W D D-M9 D-F9W D-M9 D-F9W Bore size (mm) D-A9 D-A9 D-A9 D-A9 6 10 15 20 30 32 21.5 23.5 42 44 72.5 83.5 42 44 35.5 30 32 60.5 71.5 26 28 17.5 19.5 46 48 76.5 87.5 46 48 39.5 26 56.5 67.5 Note 1) Auto switches cannot be installed