fluid temperature [C] Pump Capacity HRS090-A-20/40 HRS090-W-20/40 0.5 50 Usable range (50 Hz) Circulating fluid pressure [MPa] Circulating fluid outlet (60 Hz) 0.4 40 Pump head [m] 0.3 30 Circulating fluid outlet (50 Hz) 0.2 20 Usable range (60 Hz) 0.1 10 Circulating fluid return port 0 0 0 10 20 30 40 50 60 70 Circulating fluid flow rate [L/min] 78 Thermo-chiller Standard Type HRS090 Series

Circulating fluid head pressure head pressure Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] [m] [MPa] [m] [MPa] HRL300-Am-20 (CH1) HRL100/200/300-Am-20 (CH2) 0.9 0.6 90 60 0.8 80 0.5 50 0.7 70 Circulating fluid outlet 0.6 0.4 60 40 Usable flow rate range Circulating fluid outlet 0.5 50 0.3 30 0.4 40 0.3 0.2 30 20 Usable flow rate range 0.2 20 Circulating fluid return

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Capacity: 9 kW, Piping thread type: NPT (Rc-NPT conversion fitting included), Optional specifications: None

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: M (Applicable to Deionized Water Piping)

Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: Applicable to Deionized Water Piping

Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) Specications Model HRS090-Al-20-l HRS090-Al-40-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.15 Control method PID control Ambient temperature1 C

Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.

Applicable model HRS-WL003 HRS090-mm-20/40 Parts List q No.

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)

Cooling Capacity: 9 kW, Piping thread type: NPT (Rc-NPT conversion fitting included), Optional specifications: With earth leakage circuit breaker

Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J + M

Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: w/Automatic Fluid Fill Function

Table 2.4-20 List of set values Set value Explanation Initial value (Default setting) Sets LOCAL mode. Sets DIO mode. Sets SERIAL mode. HRS090 Series 2.4 Setting and checking 2-15 HRX-OM-T004 Chapter 2 Contact input/output communication 2.5 Contact input signal There are two contact input signals.