Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
fluid temperature [C] Pump Capacity HRS090-A-20/40 HRS090-W-20/40 0.5 50 Usable range (50 Hz) Circulating fluid pressure [MPa] Circulating fluid outlet (60 Hz) 0.4 40 Pump head [m] 0.3 30 Circulating fluid outlet (50 Hz) 0.2 20 Usable range (60 Hz) 0.1 10 Circulating fluid return port 0 0 0 10 20 30 40 50 60 70 Circulating fluid flow rate [L/min] 78 Thermo-chiller Standard Type HRS090 Series
fluid flow rate [L/min] Circulating fluid flow rate [L/min] [m] [MPa] [m] [MPa] HRL300-Am-40 (CH1) HRL100/200/300-Am-40 (CH2) 0.6 0.9 90 60 0.8 80 0.5 50 0.7 70 Circulating fluid outlet 0.6 0.4 60 40 Usable flow rate range Circulating fluid outlet 0.5 50 0.3 30 0.4 40 0.3 0.2 30 20 Usable flow rate range 0.2 20 Circulating fluid return port Circulating fluid return port 0.1 10 0.1 10 0 0
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Applicable model HRL-BB002 HRLE050-m-m HRL-BB001 HRLE090-m-m y u t Parts List r i No. Description Material Applicable model Size Qty.
Applicable model HRS-WL003 HRS090-mm-20/40 Parts List q No.
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: J (w/Automatic Fluid Fill Function)
HRSE Power supply HRZ 40 3-phase 380 to 415 VAC (50/60 Hz) Specifications HRZD Model HRSH100-Wl-40-l HRSH150-Wl-40-l HRSH200-Wl-40-l HRSH250-Wl-40-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.45 1.95 1.95 1.95 Control method PID control Ambient temperature/Altitude Note 1), 8) C Temperature: 2 to 45, Altitude: less than 3000 m HRW HECR Circulating
Pump Capacity HRS100/150-Am-20/40-m HRS100/150-Wm-20/40-m 0.5 50 Circulating fluid pressure [MPa] HRS Circulating fluid outlet (60 Hz) Usable range (50 Hz) 0.4 40 HRS 090 Pump head [m] 0.3 30 Usable range (60 Hz) HRS 100/150 HRS 100/150 Circulating fluid outlet (50 Hz) 0.2 20 HRSH 090 Circulating fluid return port 0.1 10 HRSH 0 0 0 10 20 30 40 50 60 70 HRSE Circulating fluid flow rate [L
For installation indoors, ventilation ports and a ventilation fan should be equipped as needed. 300 mm or more 500 mm or more 100 mm or more Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Power supply 100 V type Power supply 200/230 V type Less than 1000 m 35 40 1.00 Less than 1500 m 34 38 0.85 Less than 2000 m 33 36 0.80 Less than 2500 m 32 34 0.75 Less
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: M (Applicable to Deionized Water Piping)
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: Applicable to Deionized Water Piping