SMC Corporation of America
Elite Part Number Search
Search Results "HRS060-WN-20-B"

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJM (B + J + M)

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)

Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping

Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

2 VA (AC), 2 W (DC) Operating voltage: AC, DC 100 V or less Model A B C D Applicable model IS10M-20-A 10.6 74.2 64.4 28 AC20l-B IS10M-30-A 12.6 84.5 70.5 30 AC25l-B, AC30l-B IS10M-40-A 14.6 93.3 75.3 36 AC40l-B IS10M-50-A 16.6 97.3 77.3 44 AC40l-06-B IS10M-60-A 22 92.5 68.5 53 AC50l-B, AC55l-B, AC60l-B Maximum operating current 12 V to 24 VAC, DC: 50 mA 48 VAC, DC: 40 mA 100 VAC, DC: 20

-A-20-(BJM) . 9-5 9.3.2 HRS060-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS060--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS060-A-20-(BJM) . 9-7 9.5.2 HRS060-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS060--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-R005 Contents 9.9 Sample DoC. . 9-10 9.10 Daily

HRS050-A-20, HRS050-W-20Read before using. HRS060-A-20, HRS060-W-20Thank you for purchasing SMCs Thermo-chiller. 2.

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Type: -, Cooling Method: -, Cooling Capacity: 4,900/5,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping

Cooling Capacity: Cooling Capacity: 4900/5900, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M