Search Results "HRS050-AN-20-BJM"

-A-20-(BJM) . 9-5 9.3.2 HRS050-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS050--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS050-A-20-(BJM) . 9-7 9.5.2 HRS050-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS050--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-O021 Contents 9.9 Sample DoC. . 9-10 9.10 Daily

This information is needed when contacting an SMC sales distributor. (It is an example of model "HRS040-A-20".)

-(BJM) . 9-5 9.3.2 HRS060-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS060--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS060-A-20-(BJM) . 9-7 9.5.2 HRS060-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS060--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-R005 Contents 9.9 Sample DoC. . 9-10 9.10 Daily Check

) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.

This information is needed when contacting an SMC sales distributor. THERMO CHILLER HRS050-A-20-R Model Number POWER SUPPLY SERIAL No. XQ001(MAR.2019) Serial Number (SERIAL No.)

--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water flow (for water-cooled

Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRS030--20-(BJM) 0.3 Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] 20 Outlet60Hz 0.2 Pump head[m] 10 0.1 Outlet50Hz Return port 0.0 5 0 10 20 30 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS030--20-(BJM)) 9.6.2 HRS030--20-T 0.8 80 0.7 Circulating fluid pressure[MPa] 70 Availavel area 0.6 60 0.5 Pump head[

For pipe thread type N, an NPT thread conversion fitting set is included. 19 Not included for Option Z (Removed parts) 20 Not included for Options Z and Z1 (Removed parts) 15 Thermo-chiller/Rack Mount Type HRR Series Specifications: 200 to 230 VAC Water-cooled Refrigeration Model HRR012-W-20 HRR018-W-20 HRR024-W-20 HRR030-W-20 Cooling method Water-cooled refrigeration Refrigerant R410A

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJM (B + J + M)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJM (B + J + M)

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None