Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
-A-20-(BJM) . 9-5 9.3.2 HRS050-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS050--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS050-A-20-(BJM) . 9-7 9.5.2 HRS050-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS050--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-O021 Contents 9.9 Sample DoC. . 9-10 9.10 Daily
This information is needed when contacting an SMC sales distributor. (It is an example of model "HRS040-A-20".)
-(BJM) . 9-5 9.3.2 HRS060-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS060--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS060-A-20-(BJM) . 9-7 9.5.2 HRS060-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS060--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-R005 Contents 9.9 Sample DoC. . 9-10 9.10 Daily Check
) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.
This information is needed when contacting an SMC sales distributor. THERMO CHILLER HRS050-A-20-R Model Number POWER SUPPLY SERIAL No. XQ001(MAR.2019) Serial Number (SERIAL No.)
--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water flow (for water-cooled
Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRS030--20-(BJM) 0.3 Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] 20 Outlet60Hz 0.2 Pump head[m] 10 0.1 Outlet50Hz Return port 0.0 5 0 10 20 30 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS030--20-(BJM)) 9.6.2 HRS030--20-T 0.8 80 0.7 Circulating fluid pressure[MPa] 70 Availavel area 0.6 60 0.5 Pump head[
For pipe thread type N, an NPT thread conversion fitting set is included. 19 Not included for Option Z (Removed parts) 20 Not included for Options Z and Z1 (Removed parts) 15 Thermo-chiller/Rack Mount Type HRR Series Specifications: 200 to 230 VAC Water-cooled Refrigeration Model HRR012-W-20 HRR018-W-20 HRR024-W-20 HRR030-W-20 Cooling method Water-cooled refrigeration Refrigerant R410A
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJM (B + J + M)
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJM (B + J + M)
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker / With automatic water supply / Compatible with deionized water (pure water) piping
, HRS050-A*-20*, CHILLER, 729, 480 lb
-A-20-JM-X133 Rev 2.0, CHILLER, 729, 20 lb
Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Type: -, Cooling Method: -, Cooling Capacity: 4,700/5,100 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None