SMC Corporation of America
Elite Part Number Search
Search Results "HRS024-AF-20-BJM"

,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water flow (for

) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.

-(BJM) . 9-5 9.3.2 HRS050-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS050--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS050-A-20-(BJM) . 9-7 9.5.2 HRS050-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS050--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-O021 Contents 9.9 Sample DoC. . 9-10 9.10 Daily Check

-(BJM) . 9-5 9.3.2 HRS060-W-20-(BJM) . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS060--20-(BJM) . 9-7 9.5 Heating capacity . 9-7 9.5.1 HRS060-A-20-(BJM) . 9-7 9.5.2 HRS060-W-20-(BJM) . 9-7 9.6 Pump capacity. 9-8 9.6.1 HRS060--20-(BJM) . 9-8 9.7 Required facility water flow (For water-cooled type) . 9-8 9.8 Compliance . 9-9 HRS Series HRX-OM-R005 Contents 9.9 Sample DoC. . 9-10 9.10 Daily Check

Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRS030--20-(BJM) 0.3 Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] 20 Outlet60Hz 0.2 Pump head[m] 10 0.1 Outlet50Hz Return port 0.0 5 0 10 20 30 Circulating fluid flow[L/min] Fig. 9-7 Pump capacity(HRS030--20-(BJM)) 9.6.2 HRS030--20-T 0.8 80 0.7 Circulating fluid pressure[MPa] 70 Availavel area 0.6 60 0.5 Pump head[

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-lift Pump)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: G (High Temp Environment Specs)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: GT (G + T)

Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: With earth leakage circuit breaker / High pump head specification