Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
This product is obsolete. Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER (PROPRTY JDSU), OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0181700/1900 (50/60 Hz)Air-cooled refrigeration Water-cooled refrigerationSingle-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz)
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water
) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.
/030-A-20-R . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS018-A-20--R . 9-7 9.4.2 HRS030-A-20--R . 9-7 9.5 Heating capacity . 9-8 9.5.1 HRS018-A-20-R, HRS030-A-20-R . 9-8 9.6 Pump capacity. 9-9 9.6.1 HRS018-A-20-R, HRS030-A-20-R . 9-9 9.6.2 HRS018-A-20-T-R, HRS030-A-20-T-R . 9-9 9.7 Compliance . 9-10 9.8 Sample DoC. . 9-11 9.9 Daily Check Sheet . 9-12 Chapter 10 Product Warranty . 10-1 HRS-R
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Model HRS018-A-20--R HRS030-A-20--R Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 0.39 Control method PID control Ambient temperature/Humidity/Altitude1 [C] Temperature: 5 to 45C, Humidity: 30 to 70%, Altitude: less than 3000 m Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution4 Set temperature range1 [C] 5 to 40 Cooling capacity3
Note 9) Purchase an earth leakage breaker with current sensitivity of 15 mA or 30 mA separately. (A product with an optional earth leakage breaker (option B) is also available.)
-W-20, CHILLER, 729, 130 lb
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: M + T
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: None
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)