Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
An earth leakage breaker is installed in the air dryer. This saves additional electrical wiring at the time of installation. Air dryer model IDF100FS-30-R IDF125FS-30-R IDF150FS-30-R Breaker capacity 20 A 30 A Sensitivity current: 30 mA Option symbol * Corrosion is not covered under warranty.
HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water
Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.
Air-To-Electric Signal Conversion Q: Is it possible to convert an air signal into an electrical signal? A: air-to-electric switches, MPE-BZ or MPE-BZE (includes enclosure), will turn an air signal into an electrical signal, which can be wired either normally open or closed.
Use the connector included as an accessory.
Note 9) Purchase an earth leakage breaker with current sensitivity of 15 mA or 30 mA separately. (A product with an optional earth leakage breaker (option B) is also available.)
Cooling Capacity: 030 [Cooling Capacity: 2500/2900 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: LTV (L + T + V)
Cooling Capacity: 050 [Cooling Capacity: 4500/5000 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: LTV (L + T + V)
Cooling Capacity: 030 [Cooling Capacity: 2500/2900 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: L + T + V
Cooling Capacity: 050 [Cooling Capacity: 4500/5000 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: L + T + V
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: None
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: NPT with PT-NPT Conversion Fitting Set, Option: None
-W-20, CHILLER, 729, 130 lb
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: JLV (J + L + V)
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: N (NPT with PT-NPT Conversion Fitting Set), Option: LV (L + V)