An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.
HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water
/030-A-20-R . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS018-A-20--R . 9-7 9.4.2 HRS030-A-20--R . 9-7 9.5 Heating capacity . 9-8 9.5.1 HRS018-A-20-R, HRS030-A-20-R . 9-8 9.6 Pump capacity. 9-9 9.6.1 HRS018-A-20-R, HRS030-A-20-R . 9-9 9.6.2 HRS018-A-20-T-R, HRS030-A-20-T-R . 9-9 9.7 Compliance . 9-10 9.8 Sample DoC. . 9-11 9.9 Daily Check Sheet . 9-12 Chapter 10 Product Warranty . 10-1 HRS-R
Model HRS018-A-20--R HRS030-A-20--R Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 0.39 Control method PID control Ambient temperature/Humidity/Altitude1 [C] Temperature: 5 to 45C, Humidity: 30 to 70%, Altitude: less than 3000 m Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution4 Set temperature range1 [C] 5 to 40 Cooling capacity3
Note 9) Purchase an earth leakage breaker with current sensitivity of 15 mA or 30 mA separately. (A product with an optional earth leakage breaker (option B) is also available.)
-W-20, CHILLER, 729, 130 lb
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
Direct operated, relieving style Order Made P.1.8-6 AW1000-BG AW1000 AW2000-BG AW2000 AW3000-BG AW3000 1.8-1 AW1000 to 4000 How to Order 03 BG 00 30 2N AW Option Filter Regulator 1(1) Set at 0.02 to 0.2MPa Accessory 2 6 Metal bowl Nylon bowl Description Symbol Applicable model Body size 10 20 30 40 M5 Metal bowl with level gauge (AW3000/4000 only) Bowl guard (AW2000 only) Drain guide (AW3000
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BG (B + G)
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / High-temperature environment specification
Spool/Sleeve Adapter plate r Resin t Resin End plate y Resin Piston u Resin Junction cover i Resin Light cover Part no. for mounting bolt and gasket BG-VFS3000 Replacement Parts VFS31 VFS32 VFS33/34/35 Part no. No. Description Material Return spring Gasket Stainless steel NBR VFS3000-17-1 VFS3000-20 VFS3000-20 VFS3000-17-2 VFS3000-20 o !0 !
surfaces, same surface) 1 20 D-Y7BA n 20 + 45 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces, same surface) 1 15 D-P3DWA n (Different surfaces, same surface) 15 + 50 (n 2) 2 (n = 2, 4, 6, 8)*1 2 (Different surfaces, same surface) 1 15 D-P4DW n 15 + 65 (n 2) 2 (n = 2, 4, 6, 8)*1 *1 When n is an odd number, an even number that is one larger than the odd number is to be used for the calculation
Rod clevis: GKM (ISO 8140) l1 [mm] Bore size [mm] Part no. e b d f h11 (Shaft) f H9 (Hole) l1 c (Min.) a (Max.) 32 GKM10-20 M10 x 1.25 10+0.5 +0.15 40 10 10 52 20 20 40 GKM12-24 M12 x 1.25 12+0.5 +0.15 48 12 12 62 24 24 50, 63 GKM16-32 M16 x 1.5 16+0.5 +0.15 64 16 16 83 32 32 80, 100 GKM20-40 M20 x 1.5 20+0.5 +0.15 80 20 20 105 40 40 125 GKM30-54 M27 x 2 30+0.5 +0.15 110 30 30 148 54 55
Shown below is an example of a model selection procedure for an intermediate stop application (including an emergency stop in operation).
BE e 4-MA Effective thread depth MB (To attach eyebolt) f l 15 h + l ZZ1 + l + Stroke Bore size (mm) Stroke range (mm) J M AL B C E F FA GA K KA N A BA BB BC BD BG BE BZ BV BW BP D EA GB GC H MM P BY MB MA 125 140 160 180 200 250 14 14 14 17 17 20 15 15 17 20 20 25 31 31 36 41 46 56 19 19 22 26 26 30 47 47 53 60 60 67 43 43 43 48 48 60 35 35 39 39 39 49 50 50 56 63 63 71 1/4 1/4 1/4 3/8
(mm) BF VA 4H9 4H9 5H9 6H9 6H9 ZD 6 10 12 16 20 ZH M3 x 0.5 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 UC M5 x 0.8 M5 x 0.8 M6 x 1 M8 x 1.25 M8 x 1.25 ZJ 3.5 4.5 5 7 8 ZI 6 10 12 16 20 ZG 15 16 18 22 26 ZF 20 21 28 32 41 BG ZE 5 8 10 14 17 CC 9.5 13.5 17.5 20 25 VB 4 4 5 6 6 AJ 9 9 11 13 13 UE 5.5 5.5 6.6 8.6 8.6 AH 9 12 15 18 20 UD 10 10 12 16 16 AG 26 27 33 35 45 FX 22 26 32 40 50 AF 35 36 44
20 50 98 70 84 44.5 11 6.4 117.5 16 3.3 316 280 46 20 196 11 20 98 50 70 44.5 84 13 319 11 6.4 117.5 3.3 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
SB) 7 5 5 5 3 7.5 5 3 5 3 90 90 5 90 5 A MHZ 20 20 20 20 (3 x SA) 20 20 MHF Section SD SD MHL MHSJ3-63D MHSJ3-80D MHR MHK 4 MHS 10 4 11 MHC 3 5 3 5 90 90 MHT 5 MHY 20 20 20 20 MHW -X (mm) L 2H9 3H9 4H9 6H9 8H9 J 20 21 24 28 32 HB 65 75 88 106 130 HA 76 86 103 125 158 FX 22 26 32 40 50 EO 15.5 19 24 31 41 EC 11.5 15 18 23 31 DO 35.5 40 48 59 73 DC 31.5 36 42 51 63 AE 36 37 46 50 57 CA 9.5