Your search for HRS returned 21 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 10 hits in the keyword search.
Product Information » New Products Search Results
Face seal fittings: R, NPT, G 1. Tighten fittings with sealant using the proper tightening torques in the table below. 2. Chamfer dimension of R and NPT thread with sealant, and Uni thread Connection thread size (R, NPT, G) Proper tightening torque (Nm) 1/16, 1/8 3 to 5 1/4 8 to 12 3/8 15 to 20 1/2 20 to 25 D Rz 12.5 45 2.
HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water
Fig 1.2-1 Communication port (HRS012--HRS018--HRS024--20HRS030--20HRS040--20-) Fig 1.2-2 Communication port (HRS050--20HRS060--20-) HRS Series 1.2 Communication port 1-3 HRX-OM-M091 Chapter 1 Read before using 1.3 Key operations Fig 1.3-1 Key operation (1/2) and Fig 1.3-2 Key operation (2/2) show the operation of keys of the thermo-chiller.
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-lift Pump)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: With earth leakage circuit breaker / High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: High pump head specification
Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T
-W-20, CHILLER, 729, 130 lb