Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)

Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Terminal block for signal 4 x 20 7122 20 7001 75 94 107 752 Drain tube (O.D. 10, Length approx. 2 m) (Can also be connected on the other side.)

fluid pressure [Mpa] 20 Outlet60Hz 0.2 Pump head [m] 10 0.1 Outlet50Hz Return port 0.0 0 10 20 30 Circulating fluid flow [L/min] Fig 9.6-1 Pump capacity(HRS018/030--20-R) 9.6.2 HRS018-A-20-T-R, HRS030-A-20-T-R 0.8 80 0.7 70 available area Circulating fluid pressure [MPa] 0.6 60 Pump head[m] 0.5 50 Outlet: 60Hz 0.4 40 0.3 30 Outlet: 50Hz 0.2 20 available area 0.1 10 Return port 0.0 0 0 5

HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water

Model HRS018-A-20--R HRS030-A-20--R Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 0.39 Control method PID control Ambient temperature/Humidity/Altitude1 [C] Temperature: 5 to 45C, Humidity: 30 to 70%, Altitude: less than 3000 m Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution4 Set temperature range1 [C] 5 to 40 Cooling capacity3

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None

Note 10) Front: 1 m, height: 1 m, stable with no load, Other conditions Note 4) Note 11) Weight in the dry state without circulating fluids Note 12) Required flow rate when a load for the cooling capacity is applied at a circulating fluid temperature of 20C, and rated circulating fluid flow rate and facility water temperature of 25C. 2

Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: F (G with PT-G conversion Fitting Set), Option: None

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-lift Pump)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: With earth leakage circuit breaker / High pump head specification