SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-WF-20"

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-lift Pump)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping

Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: High pump head specification

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Automatic Water Supply Function

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter

) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.

. 9-11 9.5.2 HRS012--20,HRS018--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility

HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

0 5 10 15 20 25 Circulating fluid flow rate [L/min] Circulating fluid flow rate [L/min] HRR050-A-20, HRR050-W-20 0.5 Circulating fluid pressure [MPa] Outlet: 60 Hz 0.4 0.3 Outlet: 50 Hz Return port Return port (Option Z) 0.2 Allowable operating range 0.1 0 0 10 20 30 40 Circulating fluid flow rate [L/min] Required Facility Water Flow Rate 012 018 024 030 HRR -W HRR010-W-20 30 20 Facility

KK KK EA MM MM B B E/2 4-NT ND Deep SN + Stroke (A + B) Stroke B Stroke A G C A TN C G A E XT XT LD + Stroke (A + B) WF WF ZZ + Stroke (A + B) (in) ZZ PC KK Y R XT G A LD Bore (in) DD C NT ND AA EA D B MM WF P K E SN TN EE 9.44 1.30 7/16-20 1.71 1.43 1 15/16 1.26 3/4 7.44 150 (1.5") 1/4-28 3/8 1/4-20 9/32 2.02 0.3 9/16 1 1/8 5/8 1 2.36 9/32 2 5.56 5/8 3/8 9.52 1.30 7/16-20 1.71 1.84 1 15

25C Ambient temperature 2C 0.5 0.5 Ambient temperature 2C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] HRLE050-W-20 HRLE050-W-20 [50 Hz] [60 Hz] 2 2 Heating capacity [kW] Heating capacity [kW] 1.5 1.5 Facility water temperature 25C, 32C, 40C Facility water temperature 25C, 32C, 40C 1 1 0.5 0.5 0 0 15 20 25 Circulating fluid temperature [C] 15

-Am-20 (CH1) HRL100-Am-20 (CH1) 0.6 0.6 60 60 0.5 0.5 50 50 Circulating fluid outlet Circulating fluid outlet 0.4 0.4 40 40 Usable flow rate range Usable flow rate range 0.3 0.3 30 30 0.2 0.2 20 20 Circulating fluid return port 0.1 0.1 10 10 Circulating fluid return port 0 0 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Pump Circulating fluid Pump