) Note 10) Note 10) Note 10) Note 10) Note 10) use pressure within the specification range.
-A-0 HRS018-A-0 HRS024-A-20 . 9-7 9.3.2 HRS012-W-0 HRS018-W-0 HRS024-W-20 . 9-7 9.4 Cooling capacity . 9-8 9.4.1 HRS012--10-(BJMT) . 9-8 9.4.2 HRS018--10-(BJMT) . 9-8 9.4.3 HRS012--20-(BJMT) . 9-9 9.4.4 HRS018--20-(BJMT) . 9-9 9.4.5 HRS024--20-(BJMT) . 9-9 9.4.6 Option G [High temperature type] . 9-10 9.5 Heating capacity . 9-11 HRS Series HRX-OM-M090 Contents 9.5.1 HRS012--10,HRS018--10
HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: BMT (B + M + T)
Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / Compatible with deionized water (pure water) piping / High pump head specification
024 030 HRR -W HRR010-W-20 30 20 Facility water flow rate [L/min] Facility water flow rate [L/min] HRR030-W 25 15 HRR024-W 20 15 10 10 HRR018-W 5 5 HRR012-W 0 0 0 10 20 30 40 0 10 20 30 40 50 Facility water inlet temperature [C] Facility water inlet temperature [C] * This is the required facility water flow rate at the circulating fluid rated flow and the cooling capacity listed in the
W: 13 [kW] w Derive the heat generation amount from the power supply output.
Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS012-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
~024-A/W-10/20, CHILLER, 729, 100 lb
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BMT (B + M + T)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / Compatible with deionized water (pure water) piping / High pump head specification
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BMT (B + M + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BMT (B + M + T)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BMT (B + M + T)