HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
No change in external dimensions of this product Pump Capacity HRR012/018--10-T/MT 0.6 Circulating fluid pressure [MPa] 0.5 Allowable operating range 0.4 Outlet: 60 Hz 0.3 Outlet: 50 Hz Return port 0.2 Return port (Option Z1) Allowable operating range 0.1 Return port (Option Z) 0 0 10 5 15 20 25 Circulating fluid flow rate [L/min] HRR012/018/024/030-mm-20-MT HRR012/018/024/030-mm-20-T 0.6
25C Ambient temperature 2C 0.5 0.5 Ambient temperature 2C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] HRLE050-W-20 HRLE050-W-20 [50 Hz] [60 Hz] 2 2 Heating capacity [kW] Heating capacity [kW] 1.5 1.5 Facility water temperature 25C, 32C, 40C Facility water temperature 25C, 32C, 40C 1 1 0.5 0.5 0 0 15 20 25 Circulating fluid temperature [C] 15
-Am-20 (CH1) HRL100-Am-20 (CH1) 0.6 0.6 60 60 0.5 0.5 50 50 Circulating fluid outlet Circulating fluid outlet 0.4 0.4 40 40 Usable flow rate range Usable flow rate range 0.3 0.3 30 30 0.2 0.2 20 20 Circulating fluid return port 0.1 0.1 10 10 Circulating fluid return port 0 0 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Pump Circulating fluid Pump
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-pressure Pump)
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: High-pressure Pump
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BM (B + M)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: With earth leakage circuit breaker / Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Earth Leakage Breaker
+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW t e q IN OUT t e q r IN OUT w r w AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.