SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-AF-10-BJMW"

For AF40-A AF, AW only (Except AF10-A, AF50-A, AF60-A, AW10-A) 35 mm reduction New New Body size 10, 50, 60 added!

9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018-10-MT 0.8 80 0.7 70 Circulating fluid pressure [MPa] 0.6 60 0.5 Pump head [m] Available area 50 0.4 Outlet60Hz 40 0.3 30 Outlet50Hz 0.2 20 Return port 0.1 10 Available area 0.0 0 0 5 10 15 20 25 5 Circulating fluid flow [L/min] Fig 9.6-3 Pump capacity(HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT) 9.6.4 HRS012--20-T, HRS018

HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: -

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-pressure Pump)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Automatic Water Supply Function

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: High-pressure Pump

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Earth Leakage Breaker

Applicable model HRR012/018--10-T/MT*1 HRR012/018/024/030--20-T HRR012/018/024/030--20-MT1 Pump Rated flow (50/60 Hz)2, 3 L/min 7 (0.36 MPa)/10 (0.42 MPa) 10 (0.42 MPa)/14 (0.40 MPa) 10 (0.32 MPa)/14 (0.32 MPa) Maximum pump head (50/60 Hz) m 50 50 50 Output W 350 550 Circuit protector A 15 15 (10 A for standard) Recommended earth leakage breaker capacity A 15 Cooling capacity4 W The cooling

-Am-20 (CH1) HRL100-Am-20 (CH1) 0.6 0.6 60 60 0.5 0.5 50 50 Circulating fluid outlet Circulating fluid outlet 0.4 0.4 40 40 Usable flow rate range Usable flow rate range 0.3 0.3 30 30 0.2 0.2 20 20 Circulating fluid return port 0.1 0.1 10 10 Circulating fluid return port 0 0 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Pump Circulating fluid Pump