HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
Part number Applicable model A dimension [mm] Weight [kg] HRR010-m-20-mUY 330 HRR012/018-m-10-mUY 417 HRR012/018-m-20-mY HRR024/030-m-20-mY 506 HRR050-A-20-mUY 815 HRR050-W-20-mUY 637 HRR-KS001 Approx. 7 83 mm A Adjuster foot Caster (O.D.: 63) 303 mm 372 mm 494 mm 428 mm 544 mm Mounting view (HRR012/018-A) Anti-quake bracket A Anti-quake bracket B Hexagon nut Hexagon bolt Caster adjuster-foot
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-A-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-W-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.
Power supply output VI: 20 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 20 [kVA] x 0.85 = 17 [kW] Cooling capacity = Considering a safety factor of 20%, 17 [kW] x 1.2 = W Efficiency Q = P = In this example, using an efficiency of 0.7: 13 0.7 = = 18.6 [kW] Cooling capacity = Considering a safety factor of 20%, 18.6 [kW] x 1.2 = 22.3 [kW] 20.4 [kW] *1
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BYPASS KIT - HRS012-A-20-X047, OTHERS, HRS THERMO-CHILLERS, 27, HRS NO SIZE EUROPEAN
-A-20 BY DIA, OTHERS, HRS THERMO-CHILLERS, 27, HRS NO SIZE EUROPEAN
OUTLET PIPE ASSY, HRS012~024-A-20, CHILLER, 729, 250 lb
OUT PIPE ASSY, HRS012~024-A-10/20, CHILLER, 729, 200 lb
PIPE ASSY, HRS012~024-A/W-20, CHILLER, 729, 400 lb
~024-A/W-10/20, CHILLER, 729, 100 lb
A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?
A large digital display provides a clear view of the current and set values.
A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-W-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc