Y100-A Y200-A Y300-A Y400-A Y500-A Seal HNBR (NBR) Note 1) Y120P-050AS Note 2) Y220P-050S Y320P-050S Y420P-050S Y520P-050S Note 1) ( ): Size 10 Note 2) Assembly of 2 O-rings Spacer with Bracket K D F H J G E E Center of F.R.L. body B C EE (Y100T-A, Y200T-A only) Seal A (Spacer width) Model A B C D E EE F G H J K Applicable model Y100T-A 6 56 24.5 43.6 20 27 6.8 4.5 13 3 25 AC10-A Y200T-A

. 17 If option Earth leakage breaker type is selected, the earth leakage breaker is used instead of the circuit protector. 9.1 Specifications List HRS Series 9-2 HRX-OM-M090 Chapter 9 Documents Table 9-2 Specifications List [HRS--20-BGJMT] Model HRS012-A HRS012-W HRS018-A HRS018-W HRS024-A HRS024-W -20-BGJMT -20-BGJMT -20-BGJMT -20-BGJMT -20-BGJMT -20-BGJMT Air-Cooled Water-Cooled Air-Cooled

HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

Part number Applicable model A dimension [mm] Weight [kg] HRR010-m-20-mUY 330 HRR012/018-m-10-mUY 417 HRR012/018-m-20-mY HRR024/030-m-20-mY 506 HRR050-A-20-mUY 815 HRR050-W-20-mUY 637 HRR-KS001 Approx. 7 83 mm A Adjuster foot Caster (O.D.: 63) 303 mm 372 mm 494 mm 428 mm 544 mm Mounting view (HRR012/018-A) Anti-quake bracket A Anti-quake bracket B Hexagon nut Hexagon bolt Caster adjuster-foot

Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.

Power supply output VI: 20 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 20 [kVA] x 0.85 = 17 [kW] Cooling capacity = Considering a safety factor of 20%, 17 [kW] x 1.2 = W Efficiency Q = P = In this example, using an efficiency of 0.7: 13 0.7 = = 18.6 [kW] Cooling capacity = Considering a safety factor of 20%, 18.6 [kW] x 1.2 = 22.3 [kW] 20.4 [kW] *1

HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: J (Automatic Water Supply Function)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With automatic water supply

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Automatic Water Supply Function

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: Automatic Water Supply Function

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: Automatic Water Supply Function

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb