SMC Corporation of America
Elite Part Number Search
Search Results "HRR050-W-20-DMU"

HRR050-A-20/40.9-10 HRR Series HRX-OM-X071 Contents 9.3.2 HRR050-W-20/40. 9-10 9.4 Cooling capacity . 9-11 9.4.1 HRR050-A-20. 9-11 9.4.2 HRR050-W-20. 9-11 9.4.3 HRR050-A-40. 9-12 9.4.4 HRR050-W-40. 9-12 9.5 Heating capacity . 9-13 9.5.1 HRR050-A/W-20. 9-13 9.5.2 HRR050-A/W-40. 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR050-A/W-20. 9-14 9.6.2 HRR050-A/W-40. 9-14 9.7 Required facility water flow

024 030 HRR -W HRR010-W-20 30 20 Facility water flow rate [L/min] Facility water flow rate [L/min] HRR030-W 25 15 HRR024-W 20 15 10 10 HRR018-W 5 5 HRR012-W 0 0 0 10 20 30 40 0 10 20 30 40 50 Facility water inlet temperature [C] Facility water inlet temperature [C] * This is the required facility water flow rate at the circulating fluid rated flow and the cooling capacity listed in the

Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMU (DM+U)

Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: DMU (DM+U)

Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)

Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)

Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DM+U

Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -

Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -

Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR010-A/W-10/20-Y HRR012/018-A/W-10/20-Y HRR-TK001 Nut (M8) HRR024/030-A/W-20-Y Bolt (M8) HRR050-A/W-20-Y Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.

Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMU (DM+U)

Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMU (DM+U)

Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMU (DM+U)

Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)

Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -

Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet and No Rack Mounting Brackets)

Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None

Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: None, Option 2: w/Feet and No Rack Mounting Brackets