Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: T1U (T1+U))
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: TU (T+U)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option: Conforming to UL Standards
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option: M+T+U
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option: High-pressure Pump Mounted
THERMO CHILLER, CHILLER, 729, 43 lb
Thermo-chiller, Rack Mount, air cooled, CHILLER, 729, 46 lb
Thermo-chiller, Rack Mount, air cooled, CHILLER, 729, 46 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 46.00000 lb
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 46.00000 lb
-A/W-10/20. 9-11 HRR Series HRX-OM-W002 Contents 9.4.2 HRR018-A/W-10/20. 9-11 9.4.3 HRR024-A/W-20. 9-12 9.4.4 HRR030-A/W-20. 9-12 9.5 Heating capacity . 9-13 9.5.1 HRR012-A/W-10-,HRR018-A/W-10-. 9-13 9.5.2 HRR012-A/W-20,HRR018-A/W-20 . 9-13 9.5.3 HRR024-A/W-20,HRR030-A/W-20 . 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR012/018/024/030-A/W. 9-14 9.6.2 HRR012/018-A/W-10-T/MT . 9-14 9.6.3 HRR012/018
Part number Applicable model A dimension [mm] Weight [kg] HRR010-m-20-mUY 330 HRR012/018-m-10-mUY 417 HRR012/018-m-20-mY HRR024/030-m-20-mY 506 HRR050-A-20-mUY 815 HRR050-W-20-mUY 637 HRR-KS001 Approx. 7 83 mm A Adjuster foot Caster (O.D.: 63) 303 mm 372 mm 494 mm 428 mm 544 mm Mounting view (HRR012/018-A) Anti-quake bracket A Anti-quake bracket B Hexagon nut Hexagon bolt Caster adjuster-foot
Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR010-A/W-10/20-Y HRR012/018-A/W-10/20-Y HRR-TK001 Nut (M8) HRR024/030-A/W-20-Y Bolt (M8) HRR050-A/W-20-Y Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.
Nipple (16xL20) FOR HRR024, CHILLER, 729, 0.004 lb
ANTI-QUAKE BRACKETS (HRR024), CHILLER, 729, 1.4 lb
MAIN BOARD FOR HRR024, CHILLER, 729, 0.13 lb
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)]
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: -
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DMU (DM+U)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: MU (M+U)