SMC Corporation of America
Elite Part Number Search
Search Results "HRR010-A-20-U"

Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None

Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None

Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: Conforming to UL Standards

Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: None, Option 2: -

Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None, Option 2: -

Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010).  This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.

Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010).  This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.

Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010).  This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply. 

Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010).  This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply. 

Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: T1U (T1+U))

Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: DMU (DM+U)

Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None

Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None

Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None

Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: -

Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: None, Option 2: -

Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: -