Required ventilation rate [m3/min] Model Heat radiation amount [kW] Differential temp. of 3C between inside Differential temp. of 6C between inside and outside of installation area HRR010-A Approx. 2 40 20 HRR012-A Approx. 2 40 20 HRR018-A Approx. 4 70 40 HRR024-A Approx. 5 90 50 HRR030-A Approx. 6 100 60 HRR050-A Approx. 10 140 70 and outside of installation area Voltage dV dt = Voltage
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Inverter Pump Mounted, Option 2: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: Inverter Pump Mounted, Option 2: -
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: T1U (T1+U))
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option: T1+U)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: T1U (T1+U))
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: T1U (T1+U))
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: T1+U)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: T1+U)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: Inverter Pump Mounted, Option 2: -
Caster adjuster-foot kit HRR010/050-Y, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 10 lb
Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010). This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.
Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010). This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.
Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010). This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.
Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010). This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: T1U (T1+U))
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: T1U (T1+U))