Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 39 L/min, CH2 Optical Head, Size 300 Only
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 39 L/min, CH2 Optical Head, Size 300 Only
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head
Dual Channel Chiller for Lasers, HRS090 AND LARGER CAPACITIES, O88, 330 lb
Dual Channel Chiller for Lasers, HRS090 AND LARGER CAPACITIES, O88, 330 lb
Dual Channel Chiller for Lasers, HRS090 AND LARGER CAPACITIES, O88, 330.00000 lb
Documents 9.2.3 HRL300-A-40 .
40 HRS090 Standard type 0.5 5 to 35 Indoor use (400 V as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option)
This information is needed when contacting an SMC sales distributor. Model number Serial number Kind and amount of refrigerant * (An example of "HRL300-A-20" model.) "3~" stands for "3 inter phase".
This information is needed when contacting an SMC sales distributor. Model number Serial number 41A Kind and amount of refrigerant 315 * (An example of "HRL300-A-20" model.) "3~" stands for "3 inter phase".
(Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.Options to select continuous monitoring or monitoring during operation are available. Also, the detection start time after the start of operation and the detection end time can be set.
Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications Model HRL100-Am-20 HRL200-Am-20 HRL300
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Thermistor Sensor for HRL300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 12 lb
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]