HRL300-A-40 CH1 . 9-13 9.4.4 HRL100/200/300-A-40 CH2 . 9-13 9.4.5 HRL100-A-40-T2 CH1 . 9-14 9.4.6 HRL200-A-40-T2 CH2 . 9-14 9.4.7 HRL300-A-40-T2 CH1 . 9-15 9.4.8 HRL100/200/300-A-40-T2 CH2 . 9-15 9.4.9 HRL300-A-40-T3 CH1 . 9-16 9.4.10 HRL300-A-40-T3 CH2 . 9-16 9.4.11 HRL100-W-40 CH1 . 9-17 9.4.12 HRL200-W-40 CH1 . 9-17 9.4.13 HRL100/200-W-40 CH2 . 9-18 9.4.14 HRL100-W-40-T2 CH1 . 9-18 HRL
bolt mounting position (View A) For piping port sizes, refer to the Parts Description on page 5. 3 Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series Dimensions HRL300-A-40 Ventilation air inlet Ventilation air inlet Ventilation air outlet 850 40 or less 1079 330 10 1839 A 1145 1109 4 x 12 700 750 Anchor bolt mounting position (View A) For piping port sizes, refer
20 . 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100-A-20 CH1 . 8-7 8.4.2 HRL200-A-20 CH1 . 8-7 8.4.3 HRL300-A-20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity
Sound noise:HRL100-A-20 : 75 dB(A) HRL200-A-20 : 75 dB(A) HRL300-A-20 : 71 dB(A) * Front 1m, height 1m, rated condition 3.2 Installation HRL Series 3-6 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.2.3 Installation and maintenance space It is recommended to keep the space around the product shown in Fig. 3-3.
30 40 50 Sensitivity current [mA] 30 Rated operating current4 [A] 17 32 41 Rated power consumption4 [kW(kVA)] 5.4 (5.9) 10.5 (11.0) 13.1 (14.2) Noise level (Front 1 m/Height 1 m)4 [dB(A)] 75 75 71 Accessories Operation Manual (for installation/operation) 2 pcs.
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Thermistor Sensor for HRL300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 12 lb
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T3 (39 L/min, CH2 Optical Head, Size 300 Only)
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T3 (39 L/min, CH2 Optical Head, Size 300 Only)
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 39 L/min, CH2 Optical Head, Size 300 Only
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 39 L/min, CH2 Optical Head, Size 300 Only
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: 300 (CH1: 26 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: CH1: 26 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -