20 . 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100A20 CH1 . 8-7 8.4.2 HRL200A20 CH1 . 8-7 8.4.3 HRL300A20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity . 8
Model HRL100-Am-20 HRL200-Am-20 HRL300-Am-20 CH1 CH2 CH1 CH2 CH1 CH2 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 1.4 2.2 3.0 Control method PID control Ambient temperature [C] 2 to 45 Circulating uid CH1: Tap water/CH2: Tap water, Deionized water1 Set temperature range [C] CH1: 15 to 25/CH2: 20 to 40 Cooling capacity2 [kW] 9 18 19 18 26 18 Heating
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Noise Filter for HRL200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 1.1 lb
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 20 L/min, CH2 Optical Head
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: CH1: 19 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head