Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 20 L/min, CH2 Optical Head
HRX-OM-Y120-D Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type Water-Cooled refrigerated type HRL100-A-20/40 HRL100-W-40 HRL200-A-20/40 HRL200-W-40 HRL300-A-20/40 HRL400-A-40 Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: -
(Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.Options to select continuous monitoring or monitoring during operation are available. Also, the detection start time after the start of operation and the detection end time can be set.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications Model HRL100
DI Sensor for HRL100/200/300-A*-20/40, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Motor Breaker for HRL100/200/300-A*-40, HRS090 AND LARGER CAPACITIES, O88, 260 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Thermistor Sensor HRL100/200/300-A-20/40, HRS090 AND LARGER CAPACITIES, O88, 10 lb
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -