HRL200-W-40-T2 CH1 .9-19 9.4.16 HRL100/200-W-40-T2 CH2 .9-19 9.5 Pump Capacity . 9-20 9.5.1 HRL100-A/W-40 CH1 .9-20 9.5.2 HRL200-A/W-40 CH1 .9-20 9.5.3 HRL300-A-40 CH1 .9-21 9.5.4 HRL-A/W-40 CH2 .9-21 9.5.5 HRL100/200/300-A/W-40-T2 CH1 .9-22 9.5.6 HRL300-A-40-T3 CH2 .9-22 9.6 Types of Hazard Labels . 9-23 9.6.1 Positions of danger warning label .9-24 9.7 Standards . 9-25 9.8 Daily Check

. 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100-A-20 CH1 . 8-7 8.4.2 HRL200-A-20 CH1 . 8-7 8.4.3 HRL300-A-20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity . 8-9 8.5.1 HRL100-A-20 CH1 . 8-9 8.5.2 HRL200-A-20 CH1 . 8-9 8.5.3 HRL300A20 CH1 . 8-10 8.5.4 HRL-A-20CH2

. 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100A20 CH1 . 8-7 8.4.2 HRL200A20 CH1 . 8-7 8.4.3 HRL300A20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity . 8-9 8.5.1 HRL100A20 CH1 . 8-9 8.5.2 HRL200A20 CH1 . 8-9 8.5.3 HRL300A20 CH1 . 8-10 8.5.4 HRL-A-20 CH2 . 8-10

-Am-20 (CH1) HRL100-Am-20 (CH1) 0.6 0.6 60 60 0.5 0.5 50 50 Circulating fluid outlet Circulating fluid outlet 0.4 0.4 40 40 Usable flow rate range Usable flow rate range 0.3 0.3 30 30 0.2 0.2 20 20 Circulating fluid return port 0.1 0.1 10 10 Circulating fluid return port 0 0 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Pump Circulating fluid Pump

(Refer to 2.3.1 Setting of contact input signal type and form) If an input from an external switch is detected, it can be generated as an alarm.Options to select continuous monitoring or monitoring during operation are available. Also, the detection start time after the start of operation and the detection end time can be set.

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

Model HRL100-Am-20 HRL200-Am-20 HRL300-Am-20 CH1 CH2 CH1 CH2 CH1 CH2 Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge [kg] 1.4 2.2 3.0 Control method PID control Ambient temperature [C] 2 to 45 Circulating uid CH1: Tap water/CH2: Tap water, Deionized water1 Set temperature range [C] CH1: 15 to 25/CH2: 20 to 40 Cooling capacity2 [kW] 9 18 19 18 26 18 Heating

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: 20 L/min, CH2 Optical Head

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: -

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 20 L/min, CH2 Optical Head