Cooling Capacity HRL100-Am-40 (CH1)*1 HRL200-Am-40 (CH1)*1 30 14 12 Ambient temperature 32C 25 Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 20 8 15 6 10 4 Ambient temperature 45C Ambient temperature 45C 5 2 0 0 5 20 10 15 25 30 35 5 20 10 15 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRL300-Am-40 (CH1)*1 HRL100/200/300-Am-40 (CH2

Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications Model HRL100

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)]

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (60 Hz)], DI Option: -, Pump Option: -

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -

Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -

HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Temperature Sensor HRL100

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control)

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)

Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: CH2 w/Electric Conductivity Control, Pump Option: T2 (20 L/min, CH2 Optical Head)