Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: 20 L/min, CH2 Optical Head
Dual Channel Chiller for Laser, CHILLER, 729, 300 lb
9/1 kW Chiller, Elec Cond Cntrl, HPP, CHILLER, 729, 240 lb
. 9-12 9.4.3 HRL300-A-40 CH1 . 9-13 9.4.4 HRL100/200/300-A-40 CH2 . 9-13 9.4.5 HRL100-A-40-T2 CH1 . 9-14 9.4.6 HRL200-A-40-T2 CH2 . 9-14 9.4.7 HRL300-A-40-T2 CH1 . 9-15 9.4.8 HRL100/200/300-A-40-T2 CH2 . 9-15 9.4.9 HRL300-A-40-T3 CH1 . 9-16 9.4.10 HRL300-A-40-T3 CH2 . 9-16 9.4.11 HRL100-W-40 CH1 . 9-17 9.4.12 HRL200-W-40 CH1 . 9-17 9.4.13 HRL100/200-W-40 CH2 . 9-18 9.4.14 HRL100-W-40-T2
/200/300-A-20 . 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100-A-20 CH1 . 8-7 8.4.2 HRL200-A-20 CH1 . 8-7 8.4.3 HRL300-A-20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5
air outlet 40 or less 330 10 954 715 1538 A 1026 4 x 12 984 627 677 Anchor bolt mounting position (View A) For piping port sizes, refer to the Parts Description on page 5. 2 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Dimensions HRL200-A-40 Ventilation air inlet Ventilation air inlet Ventilation air outlet 715 40 or less 954 330 10 1538 A 1026 984 4 x 12 627 677 Anchor
/200/300-A-20 . 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100A20 CH1 . 8-7 8.4.2 HRL200A20 CH1 . 8-7 8.4.3 HRL300A20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity
30 40 50 Sensitivity current [mA] 30 Rated operating current4 [A] 17 32 41 Rated power consumption4 [kW(kVA)] 5.4 (5.9) 10.5 (11.0) 13.1 (14.2) Noise level (Front 1 m/Height 1 m)4 [dB(A)] 75 75 71 Accessories Operation Manual (for installation/operation) 2 pcs.
DI Sensor for HRL100/200/300-A*-20/40, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Motor Breaker for HRL100/200/300-A*-40, HRS090 AND LARGER CAPACITIES, O88, 260 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Pressure Sensor for HRL100/200/300-A*-20, HRS090 AND LARGER CAPACITIES, O88, 40 lb
Thermistor Sensor HRL100/200/300-A-20/40, HRS090 AND LARGER CAPACITIES, O88, 10 lb
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
A large digital display provides a clear view of the current and set values.
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: 100 (CH1: 9 kW; CH2: 1 kW), Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -
Cooling Capacity: CH1: 9 kW; CH2: 1 kW, Pipe Thread: F [G (Rc-G Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: -, Pump Option: -