Series HEC is a range of Peltier type chillers which are ideal for ensuring the constant temperature of circulating fluids. The series is available in either an air cooled (refrigerant free type), or a water cooled?version. Available in a wide range of power supply voltages, the HEC offers outstanding cooling capacity performance of between 230 and 1200W depending on the selected model.
HEC006-W2A HEC006-W2B HEC012-W2A HEC012-W2B Keep this manual available at all times. 2016 SMC CORPORATION All Rights Reserved Preface Preface Thank you very much for purchasing SMC Thermo-con. This manual is described for operation of this unit. Please use this manual for efficient and long use of this unit.
HEC002-A5* HEC006-A5* Keep this manual available at all times.
also required to connect the JXC 1 series controller and the LEC series communication cable (LEC-W2A-C).
Order the communication cable for controller setting (LEC-W2A-C) separately to use this software.
Caution (1) Do not connect any device other than the specified device (JXC-W2/W2A-C, LEC-W2/W2A-C, LEC-T1).
The controller for communication and PC are connected using the USB cable (A-miniB) LEC-W2-U and communication cable LEC-W2A-C. (When connecting the communication cable to the JXC1 series, use a conversion cable.)
Model HEC002-A5A HEC002-A5B HEC006-A5A HEC006-A5B Cooling method Thermoelectric device (Thermo-module) Radiating method Forced air cooling Control method Cooling/Heating automatic shift PID control 50 to 95F (10 to 35C), 35 to 80%RH (no condensation) Ambient temperature/humidity Circulating fluid Clear water 50 to 140F (10 to 60 C) (no condensation) Operating temperature range Circulating
Caution (1) Do not connect any device other than the specified device (JXC-W2/W2A-C, LEC-W2/W2A-C, LEC-T1). If connected to other equipment, this product may be damaged due to differences in signal wiring. (2) When connecting cables, do not allow conductors to get caught in the connector insertion port. 5.4 IN, OUT: EtherCAT communication connector E.g.)
Caution (1) Do not connect any device other than the specified device (JXC-W2/W2A-C, LEC-W2/W2A-C, LEC-T1).
SI Serial I/O connector (8 poles) Connector for the teaching box (LEC-T1) or the controller communication cable (JXC-W2A-C). ENC Encoder connector (16 poles) Connect to the actuator cable. MOT Motor driving connector (6 poles) Connect to the controller power supply (24VDC) using the power supply plug.
Connect the communication cable LEC-W2A-C to the USB port of the PC using the USB cable (LEC-W2-U). The message shown below will appear, as the driver has not yet been installed. iii. Open the Windows Start menu, right-click on Computer, select Properties and thereafter Device Manager.
Connect the communication cable LEC-W2A-C to the USB port of the PC using the USB cable (LEC-W2-U). ii. Right-click the Start menu, and select "Device Manager". Right-click 7 - iii. The COM No. is shown next to the "SMC Serial Port" in the "Ports (COM&LPT)". (In the case of the lower figure, the COM No. is "3".)
Connect the communication cable LEC-W2A-C to the USB port of the PC using the USB cable (LEC-W2-U). ii. Right click the Windows logo at the lower left of the desk top, and select Device manager. iii. Check the COM number for the RS485 communication from the Ports (COM & LPT) device SMC Serial Port. In this example it is shown as COM8.
Electric actuator *1) Prepared by user I/O cable Part No: LEC-CN5-# PLC *1) Controller Parallel I/O Signal power supply 24 VDC DC24V *5) Option *1) *5) Controller communication cable Part No:JXC-W2A-C Actuator cable Part No to SI to ENC LE-CP-#-# Conversion cable Part No:P5062-5 *2) *4) to MOT 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50
. *6) Prepared by user Electric actuator *1) I/O cable Part No: LEC-CL5PLC Connect the ground *3) *4) Power supply for I/O signal 24 VDC Driver To CN5 *5) *1) *6) Communication cable for controller setting Actuator cable Part NoLE-CP--S Part No: LEC-W2A-C USB Cable To CN3 LE-CP--B-S To CN4 LEC-W2-U (Standard cable) *2) *5) LE-CPTo CN2 LE-CP--B (Robotic type cable) Teaching box (With 3m cable
(JXC-W2A-C) See problem No. 3. The electric See problem actuator does not No. 4. operate correctly Please contact your SMC representative. 77 - Trouble No. Trouble Possible cause How to diagnose the trouble Solutions The power supply, voltage or current should be modified to an appropriate one. 4. External Wiring Diagram 5.
USB drivers for communication cables (LEC-W2A-C and LEC-W2-C) can also be downloaded.
The controller setting software can be downloaded from here.
Note) Even if you download the controller setting software, a communication cable (LEC-W2A-C) or USB cable (LEC-W2-U) is always required.
We recommend using the LEC-W2A-C (Windows 10 communication cable) for use with Windows 10.
After purchasing the cable, download the driver for the communication cable (LEC-W2A-C) onto a USB, and install it.
As for the old communication cable (LEC-W2-C), installing a driver for Window 8.1 on a Windows 10 PC may be possible, but operation is not guaranteed.
HEC001 series HEC003 series HEC012 series HEC002 series HEC006 series Keep available whenever necessary.