Type: S (Wired), Protocol: EN (EtherNet/IP™), Output Polarity: 3 (PNP, -Com; EtherNet/IP™, Dual Port; PROFINET Conformance Class C, EtherCAT®), Suffix: -X80 (EtherNet/IP™)
The EX600 serial interface offers a full suite of diagnostics and programmable parameters to meet the most stringent requirements. The EX600 offers excellent flexibility including digital input, digital output and analog input unit options. With the use of D-sub output blocks, a maximum of 9 remote D-sub manifolds can be attached to one EX600 communication module.
Allocated bytes Unit Unit part number Input Output EX600-SEN3 / 4 (32 outputs) 0 4 SI unit EX600-SEN3 / 4 (32 outputs) 4 4 (with diagnostic data) EX600-DX#B (8 inputs) 1 0 EX600-DX#C (8 inputs) 1 0 EX600-DX#C1 (8 inputs) 1 0 (with open circuit detection) Digital input unit EX600-DX#D (16 inputs) 2 0 EX600-DX#E (16 inputs) 2 0 EX600-DX#F (16 inputs) 2 0 EX600-DY#B (8 outputs) 0 1 EX600-DY#
W.S. 032767 032767 +0+32767 3276865535 -0-32767 -0-32767 15 V()50001000 4 V PLC 4000 -57No.EX-OMS0026CN EX600 byte EX600 byte EX600 byte byte EX600-SEN3/4 (32 ) 0 4 SI EX600-SEN3/4 (32 ) 4 4 () EX600-DXB (8 ) 1 0 EX600-DXC (8 ) 1 0 EX600-DXC1 (8 ) 1 0 () EX600-DXD (16 ) 2 0 EX600-DXE (16 ) 2 0 EX600-DXF (16 ) 2 0 EX600-DYB (8 ) 0 1 EX600-DYE (16 ) 0 2 EX600-DYF (16 ) 0 2 EX600-DME
Page EtherNet/IP (2 port) EX600-SEN3 EX600-SEN4 CC-Link EX126D-SMJ1 SDVB EtherCAT P.586 EX600-SEC1 EX600-SEC2 EX260 SI unit part no.
Screen for the EX600-SPN3/4 (1) (2) (4) (3) Fig. Screen for the EX600-SEN7/SEN8, and EX600-SEN3-X80 -21No.EX-OMY0032-B 8.5.2. Setting the IO-Link Module Parameters (Only possible when not connected to PLC) (for the EX600-SEN7/SEN8, and EX600-SEN3-X80 only) The following shows the procedure to set the parameters of the EX600-L#B1.
PC (Commercially available product) Switching hub (Unmanaged switch) LAN cable EX600-SEN3 IP address setting (example): Device IP address Subnet mask PC 192.168.0.253 255.255.255.0 EX260-SEN1 192.168.0.10 EX600-SEN3 192.168.0.11 Fig. Network Configuration Example -4No.EX-OMV1026-B 4. Setting the EtherNet/IPTM Device No.
While there is also an EtherNet/IP compatible made-toorder specification, the EX600-SEN3-X80, the manifold will also need to be made to order in this case.
Before Use Fieldbus system EX600-SEN3/EX600-SEN4 5 (5)Fix the manifold by tightening the DIN rail fixing screws of the EX600-ZMA2. (M4 x 20) Tightening torque: 0.7 to 0.8 Nm. The tightening torque at the valve side depends on the valve type. Refer to the operation manual of the corresponding valve manifold.
Connects up to 4 IO-Link modules per manifold (Total of 16 IO-Link devices); Supports both port class A (integrated power, sensors and regulators) and class B (separate output power, for use with valve); Process data, parameters and device information can be set and monitored using PC; Compatible with EX600-SEN3-X80, EX600-SPN3, EX600-SPN4, EX600-SEN7/8 and EX600-SEC3/4
Connects up to 4 IO-Link modules per manifold (Total of 16 IO-Link devices); Supports both port class A (integrated power, sensors and regulators) and class B (separate output power, for use with valve); Process data, parameters and device information can be set and monitored using PC; Compatible with EX600-SEN3-X80, EX600-SPN3, EX600-SPN4, EX600-SEN7/8 and EX600-SEC3/4
Connects up to 4 IO-Link modules per manifold (Total of 16 IO-Link devices); Supports both port class A (integrated power, sensors and regulators) and class B (separate output power, for use with valve); Process data, parameters and device information can be set and monitored using PC; Compatible with EX600-SEN3-X80, EX600-SPN3, EX600-SPN4, EX600-SEN7/8 and EX600-SEC3/4
._3d_items_collection = {}; } SMC AN20-C10 silencer, AN SILENCER (must be purchased in multiples of 10) $6.50 + Add to Quote Add To Cart Add to Cart SMC EX600-SEN3 si unit, EX300
EtherNet/IPTM is a trademark of ODVA. 2012 SMC Corporation All Rights Reserved 3 EX260-SEN3 ex260_sen3_22_v**.eds 4 ex260_sen4_22_v**.eds EX260-SEN4
Protocol: SEN (EtherNet/IPâ„¢, Modbus/TCP), Output Polarity/Communication Connector: 3 [16 Outputs, -COM (PNP), M12 Connector]
Type: Wireless System, Communication Protocol: EtherNet/IPTM, Output Format: Source/PNP (Negative common), Type: SI Unit, Number of Inputs/Outputs: 16, Connector: M12
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., "SI UNIT, EX, SERIAL TRANSMISSION SYSTEM, N lb
-HT1ATable of compatible units capable of communication with Handheld Terminals Version Nil Version A EX600-SPR (PROFIBUS DP) EX600-SPRA (PROFIBUS DP) EX600-SDN (DeviceNet) EX600-SDNA (DeviceNet) EX600-SMJ (CC-Link) EX600-SEN (EtherNet/IP) SI Unit EX600-SEC (EtherCAT) EX600-SPN (PROFINET) EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600
EX600-SPRl (PROFIBUS DP) EX600-SPRlA (PROFIBUS DP) EX600-SDNl (DeviceNet) EX600-SDNlA (DeviceNet) SI Unit EX600-SMJl (CC-Link) EX600-SENl (EtherNet/IP) EX600-SECl (EtherCAT) EX600-DXlB EX600-DXlCl EX600-DXlD EX600-DXlE EX600-DXlF EX600-DYlB EX600-DYlE EX600-DYlF EX600-DMlE EX600-DMlF EX600-AXA EX600-AYA EX600-AMB Digital Input Unit Digital Output Unit Digital Input/Output Unit Analog Input
EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA EX600-AYA EX600-AMB H.T.