EX250-EA1 EX250-EA2 EX600-SDN1A EX600-SDN2A EX600-SMJ1 EX600-SMJ2 EX600-SPR1A EX600-SPR2A EX600-SEN1 EX600-SEN2 EX600-SEC1 EX600-SEC2 EX600-DXNB EX600-DXPB EX600-DXNC EX600-DXNC1 EX600-DXPC EX600-DXPC1 EX600-DXND EX600-DXPD EX600-DXNE EX600-DXPE EX600-DXNF EX600-DXPF EX600-DYNB EX600-DYPB EX600-DYNE EX600-DYPE EX600-DYNF EX600-DYPE EX600-DMNE EX600-DMPE EX600-DMNF EX600-DMPF EX600-AXA EX600
EX600-SPRl (PROFIBUS DP) EX600-SPRlA (PROFIBUS DP) EX600-SDNl (DeviceNet) EX600-SDNlA (DeviceNet) SI Unit EX600-SMJl (CC-Link) EX600-SENl (EtherNet/IP) EX600-SECl (EtherCAT) EX600-DXlB EX600-DXlCl EX600-DXlD EX600-DXlE EX600-DXlF EX600-DYlB EX600-DYlE EX600-DYlF EX600-DMlE EX600-DMlF EX600-AXA EX600-AYA EX600-AMB Digital Input Unit Digital Output Unit Digital Input/Output Unit Analog Input
EX600-SPRl (PROFIBUS DP) EX600-SPRlA (PROFIBUS DP) EX600-SDNl (DeviceNet) EX600-SDNlA (DeviceNet) SI Unit EX600-SMJl (CC-Link) EX600-SENl (EtherNet/IP) EX600-SECl (EtherCAT) EX600-DXlB EX600-DXlCl EX600-DXlD EX600-DXlE EX600-DXlF EX600-DYlB EX600-DYlE EX600-DYlF EX600-DMlE EX600-DMlF EX600-AXA EX600-AYA EX600-AMB Digital Input Unit Digital Output Unit Digital Input/Output Unit Analog Input
Occupied byte Unit Unit part number Input Output EX600-SEC (32 outputs) 0 4 EX600-SEC (24 outputs) 0 3 SI unit EX600-SEC (16 outputs) 0 2 EX600-SEC (8 outputs) 0 1 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) 1 0 EX600-DXC1 (8 inputs)(with open circuit detection) 1 0 Digital input unit EX600-DXD (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs) 0 1
Model EX260-SEC1/3 EX260-SEC2/4 EX260-SPN1/3 EX260-SPN2/4 EX260-SEN1/3 EX260-SEN2/4 EtherCAT Note 2) EtherNet/IP Note 2) Protocol PROFINET Note 2) Applicable system Volume 1(Edition 3.8) Volume 2(Edition 1.9) Conformance Test Record V .1.1 XML file PROFINET Specification Version 2.2 GSD file EDS file Version Note 1) Configuration file Note 3) SEC1: 0/32 SEC3: 0/16 SEC2: 0/32 SEC4: 0/16 SPN1
-HT1ATable of compatible units capable of communication with Handheld Terminals Version Nil Version A EX600-SPR (PROFIBUS DP) EX600-SPRA (PROFIBUS DP) EX600-SDN (DeviceNet) EX600-SDNA (DeviceNet) EX600-SMJ (CC-Link) EX600-SEN (EtherNet/IP) SI Unit EX600-SEC (EtherCAT) EX600-SPN (PROFINET) EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600
EX600-SPRl (PROFIBUS DP) EX600-SPRlA (PROFIBUS DP) EX600-SDNl (DeviceNet) EX600-SDNlA (DeviceNet) SI Unit EX600-SMJl (CC-Link) EX600-SENl (EtherNet/IP) EX600-SECl (EtherCAT) EX600-DXlB EX600-DXlCl EX600-DXlD EX600-DXlE EX600-DXlF EX600-DYlB EX600-DYlE EX600-DYlF EX600-DMlE EX600-DMlF EX600-AXA EX600-AYA EX600-AMB Digital Input Unit Digital Output Unit Digital Input/Output Unit Analog Input
Symbol Number of cores 1 34 2 17 3 9 Symbol Length 1 0.6 2 1.5 3 3 107 Type 10 Connector Connecting Base Manifold Exploded View JSY1000/3000/5000 Series Note that EX600-SEC1 and EX600-SEC2 EtherCAT compatible SI units are to be discontinued as of October 2022.
End plate bracket (EX600-ZMA2) 6 12 EX600-SEC1 / EX600-SEC2 Displays the status of the power supply voltage for control and input. PWR Displays the status of the power supply voltage for outputs. Wiring PWR(V) Thank you for purchasing an SMC EX600 Series Fieldbus system.
Fieldbus serial transmission system (EX600), SI unit for input/output , Kit types include DeviceNetÖ, PROFIBUS-DP, CC-Link, EtherCAT, and EtherNet/IPÖ , 1-12 stations available as standard, MANIFOLD, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT (
High precision type [mm] H Model H LERH10 LERH30 LERH50 49 Space-saving Motor built-in 62 78 Shock-less/High speed actuation Max. speed: 420/sec (7.33 rad/sec) Max. acceleration/deceleration: 3,000/sec2 (52.36 rad/sec2) Positioning repeatability: 0.05 Repeatability at the end: 0.01 (Pushing control/With external stopper) Rotation angle 320 (310), 180, 90 The value indicated in brackets shows
Network topology Daisy chain Max. segment length Up to 100 m (328 ft) Address setting Manual setting is not required, automatically set EX260-SEC1/-SEC2 32 outputs Number of outputs EX260-SEC3/-SEC4 16 outputs Vendor ID 0114 hex (276) EX260-SEC1 0101 hex (16777217) EX260-SEC2 0102 hex (16777218) Product code EX260-SEC3 0103 hex (16777219) EX260-SEC4 0104 hex (16777220) Connectable valve series
SI unit specification Max. number of output points when the Power block is used EX250-SDN1, -SMJ2, -SPR1, -SCA1A, -SEN1 32 inputs / 32 outputs 24 points EX260-SDN1, -SDN2, -SMJ1, -SMJ2, -SPR1, -SPR2 EX260-SPR5, -SPR6, -SEN1, -SEN2, -SEC1, -SEC2 EX260-SPN1, -SPN2, -SPL1 32 outputs 24 points EX260-SDN3, -SDN4, -SMJ3, -SMJ4, -SPR3, -SPR4 EX260-SPR7, -SPR8, -SEN3, -SEN4, -SEC3, -SEC4 EX260-SPN3
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Range [Resolution] Setting Timing Acceleration Unit 45 (PnA8A) After 4 0H Reference unit/sec2 0 restart 0001H Not supported Acceleration Base Unit (Set the value of "n" used as the exponent in 10n when calculating the Acceleration Unit (45).) 46 (PnA8C) After 4 4 to 6 4 restart Torque Unit 1 to 2 0H Not supported 47 (PnA8E) After 4 1 restart 0001H Percentage (%) of rated torque 0002H
Protocol: SEC (EtherCAT®), Output Polarity/Communication Connector: 2 [32 Outputs, +COM (NPN), M12 Connector]
Type: Wireless System, Communication Protocol: EtherCAT, Output Format: Sink/NPN (Positive common), Type: SI Unit, Number of Inputs/Outputs: 32, Connector: M12