EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA EX600-AYA EX600-AMB H.T.
pcs.), 8 inputs EX600-DXNC NPN input, M8 connector, 3 pins (8 pcs.), 8 inputs EX600-DXNC1 NPN input, M8 connector, 3 pins (8 pcs.), 8 inputs, with open circuit detection EX600-DXPC PNP input, M8 connector, 3 pins (8 pcs.), 8 inputs EX600-DXPC1 PNP input, M8 connector, 3 pins (8 pcs.), 8 inputs, with open circuit detection EX600-DXND NPN input, M12 connector, 5 pins (8 pcs.), 16 inputs EX600
-HT1ATable of compatible units capable of communication with Handheld Terminals Version Nil Version A EX600-SPR (PROFIBUS DP) EX600-SPRA (PROFIBUS DP) EX600-SDN (DeviceNet) EX600-SDNA (DeviceNet) EX600-SMJ (CC-Link) EX600-SEN (EtherNet/IP) SI Unit EX600-SEC (EtherCAT) EX600-SPN (PROFINET) EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600
EX600-SPRl (PROFIBUS DP) EX600-SPRlA (PROFIBUS DP) EX600-SDNl (DeviceNet) EX600-SDNlA (DeviceNet) SI Unit EX600-SMJl (CC-Link) EX600-SENl (EtherNet/IP) EX600-SECl (EtherCAT) EX600-DXlB EX600-DXlCl EX600-DXlD EX600-DXlE EX600-DXlF EX600-DYlB EX600-DYlE EX600-DYlF EX600-DMlE EX600-DMlF EX600-AXA EX600-AYA EX600-AMB Digital Input Unit Digital Output Unit Digital Input/Output Unit Analog Input
EX600-SPRl (PROFIBUS DP) EX600-SPRlA (PROFIBUS DP) EX600-SDNl (DeviceNet) EX600-SDNlA (DeviceNet) SI Unit EX600-SMJl (CC-Link) EX600-SENl (EtherNet/IP) EX600-SECl (EtherCAT) EX600-DXlB EX600-DXlCl EX600-DXlD EX600-DXlE EX600-DXlF EX600-DYlB EX600-DYlE EX600-DYlF EX600-DMlE EX600-DMlF EX600-AXA EX600-AYA EX600-AMB Digital Input Unit Digital Output Unit Digital Input/Output Unit Analog Input
detection EX600-DXPC PNP input, M8 connector, 3 pins (8 pcs.), 8 inputs VFR EX600-DXPC1 PNP input, M8 connector, 3 pins (8 pcs.), 8 inputs, with open circuit detection Digital input unit VQ7 EX600-DXND NPN input, M12 connector, 5 pins (8 pcs.), 16 inputs EX600-DXPD PNP input, M12 connector, 5 pins (8 pcs.), 16 inputs EX600-DXNE NPN input, D-sub connector, 25 pins, 16 inputs EX600-DXPE PNP
8 x M12 (5 pins) EX600-DXB EX600-DXC/C1 EX600-DXD Specifications EX600-DXPC EX600-DXNC EX600-DXPD EX600-DXND Model EX600-DXPB EX600-DXNB PNP NPN PNP NPN PNP NPN Input type Input connector M12 (5 pins) Note 1) M12 (5 pins) Note 1) M8 (3 pins) Number of inputs 8 inputs (2 inputs/connector) 8 inputs (1 input/connector) 16 inputs (2 inputs/connector) Sensor supplied voltage 24 VDC (Supplied
-SDN1A EX600-SDN2A EX600-SMJ1 EX600-SMJ2 EX600-SPR1A EX600-SPR2A EX600-SEN1 EX600-SEN2 EX600-SEC1 EX600-SEC2 EX600-DXNB EX600-DXPB EX600-DXNC EX600-DXNC1 EX600-DXPC EX600-DXPC1 EX600-DXND EX600-DXPD EX600-DXNE EX600-DXPE EX600-DXNF EX600-DXPF EX600-DYNB EX600-DYPB EX600-DYNE EX600-DYPE EX600-DYNF EX600-DYPE EX600-DMNE EX600-DMPE EX600-DMNF EX600-DMPF EX600-AXA EX600-AYA EX600-AMB EX600-ED2
EX500-Q001 EX500-Q001-X1 EX500-Q101 EX500-Q101-X1 EX250-SDN1 EX250-SPR1 EX250-SMJ2 EX250-SAS3 EX250-SAS5 EX250-SAS7 EX250-SAS9 EX250-SCA1A EX250-SCN1 EX250-SEN1 EX250-IE1 EX250-IE2 EX250-IE3 EX250-EA1 EX600-ZMV1 EX600-SDN1 EX600-SDN2 EX600-SMJ1 EX600-SMJ2 EX600-SPR1 EX600-SPR2 EX600-DXPB EX600-DXNB EX600-DXPC EX600-DXNC EX600-DXPC1 EX600-DXNC1 EX600-DXPD EX600-DXND EX600-DYPB EX600-DYNB EX600
Allocated bytes Unit Unit part number Input Output EX600-SEN7/8 (32 outputs) 0 4 SI unit EX600-SEN7/8 (32 outputs) 4 4 (with diagnostic data) EX600-DX#B (8 inputs) 1 0 EX600-DX#C (8 inputs) 1 0 EX600-DX#C1 (8 inputs) 1 0 (with open circuit detection) Digital input unit EX600-DX#D (16 inputs) 2 0 EX600-DX#E (16 inputs) 2 0 EX600-DX#F (16 inputs) 2 0 EX600-DY#B (8 outputs) 0 1 EX600-DY#E (16
System construction status No.0 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 End EX600 EX600 EX600 EX600 EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -SEN3 plate -LAB1 -LAB1 -LBB1 -LBB1 -127No.EX-OMX1011 (6) When unit diagnostics is generated, the diagnostic information is displayed on the [SYSTEM CONFIGURATION STATUS] screen.
Fitting, Plug Part Nos. uClamp bracket for EX600 EX600 Manifold Options ZMA3 Enclosed parts Round head screw with washer (M4 x 20) 1 pc.
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WPN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (8 points) (with broken line sensor) 1 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#
Input Output EX600-W### (32 points) 0 1 4 EX600-W### (24 points) 01 3 Wireless unit WEN WSV EX600-W### (16 points) 01 2 EX600-W### (8 points) 01 1 EX600-W### (0 point) 0 1 0 EX600-DX#B (8 points) 1 0 EX600-DX#C (8 points) 1 0 EX600-DX#C1 (16 points) 2 0 Digital input unit DX EX600-DX#D (16 points) 2 0 EX600-DX#E (16 points) 2 0 EX600-DX#F (16 points) 2 0 EX600-DY#B (8 points) 0 1 EX600-DY
Allocated bytes Allocated bytes Unit Unit part number Input Output EX600-SEC3/4 (32 outputs) 0 4 EX600-SEC3/4 (24 outputs) 0 3 SI unit EX600-SEC3/4 (16 outputs) 0 2 EX600-SEC3/4 (8 outputs) 0 1 EX600-DX#B (8 inputs) 1 0 EX600-DX#C (8 inputs) 1 0 EX600-DX#C1 (8 inputs) 1 0 (with open circuit detection) Digital input unit EX600-DX#D (16 inputs) 2 0 EX600-DX#E (16 inputs) 2 0 EX600-DX#F (16
2 channels 2 channels M12 connector (5 pins) 4 pcs. tEX600 IO-Link unit EX600 Caution L 1 A B The applicable SI unit models are the PROFINET compatible EX600-SPN3 and EX600-SPN4.
Bit area Input (RX) Output (RY) EX600-WSV* (32 points) 0 32 EX600-WSV* (24 points) 0 24 EX600-WSV* (16 points) 0 16 Wireless Remote WSV EX600-WSV* (8 points) 0 8 EX600-WSV* (0 points) 0 0 EX600-DX *B (8 points) 8 0 EX600-DX *C (8 points) 8 0 EX600-DX *C1 (8 points) (with broken 8 0 Digital input unit line detection) (EX600 Series) DX EX600-DX *D (16 points) 16 0 EX600-DX *E (16 points) 16
Allocated bytes Unit Unit part number Input Output EX600-SPN3 / 4 (32 outputs) 0 4 SI unit EX600-SPN3 / 4 (32 outputs) 4 4 (with diagnostic data) EX600-DX#B (8 inputs) 1 0 EX600-DX#C (8 inputs) 1 0 EX600-DX#C1 (8 inputs) 1 0 (with open circuit detection) Digital input unit EX600-DX#D (16 inputs) 2 0 EX600-DX#E (16 inputs) 2 0 EX600-DX#F (16 inputs) 2 0 EX600-DY#B (8 outputs) 0 1 EX600-DY#
) () PLC (IP) International Protection () -11No.EX-OMN0029CN-D SI SI EX600-SDN EX600-SDNA EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA EX600-AYA EX600-AMB EX600-HT1 EX600-HT1A EX600-HT1 EX600-DEEX600-DFEX600-AYAEX600-AMB SI EX600-SDN1 EX600-SDN1A -12No.EX-OMN0029CN-D (1) 1.51.6 Nm (2) 1 10 (SI ) (3)SI
Occupied byte Unit Unit part number Input Output EX600-SEC (32 outputs) 0 4 EX600-SEC (24 outputs) 0 3 SI unit EX600-SEC (16 outputs) 0 2 EX600-SEC (8 outputs) 0 1 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) 1 0 EX600-DXC1 (8 inputs)(with open circuit detection) 1 0 Digital input unit EX600-DXD (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs) 0 1