9, @0 EX260 EX123/124/126 EX500 EX600 EX245 EX250 EX120/121/122 EX140 EX180 EX510 M8/M12 ATEX @1, @2, @4, @5 Type 1 Type 2 Type 3 Type 1 Type 2 @6, @7 @1 to @3 EX260 EX250 p. 233 p. 235 @6 to #0 @6, @9 VProduct Table Series Protocols No. Part no. Connector type Cable length EtherNet/IP End plate EX600-ED2m !

Product Number Data Transmission rate Process data size IODD File COM3 SMC-EX260-SIL1_04_3-ymmdd-IODD1.1 1 (230.4 kbps) 0 byte input/4 bytes output 2 COM2 (38.4 kbps) SMC-EX260-SIL1_04_2-ymmdd-IODD1.1 EX260-SIL1 3 COM3 SMC-EX260-SIL1_24_3-ymmdd-IODD1.1 (230.4 kbps) 2 bytes input/4 bytes output (2 bytes input: Device State) 4 COM2 (38.4 kbps) SMC-EX260-SIL1_24_2-ymmdd-IODD1.1 : "ymmdd" in

GSD file: GSDML-V2.35-SMC-EX260-FPS-*.xml Symbol file: GSDML_0083_EX260_FPS.bmp 4.1.2. Modules EX260-FPS1 consists of the following modules.

Network topology Daisy chain Max. segment length Up to 100 m (328 ft) Address setting Manual setting is not required, automatically set EX260-SEC1/-SEC2 32 outputs Number of outputs EX260-SEC3/-SEC4 16 outputs Vendor ID 0114 hex (276) EX260-SEC1 0101 hex (16777217) EX260-SEC2 0102 hex (16777218) Product code EX260-SEC3 0103 hex (16777219) EX260-SEC4 0104 hex (16777220) Connectable valve series

Refer to the SMC website or the SV series in the Best Pneumatics No. 1 for details on solenoid valve specifications, Common Precautions and Specific Product Precautions. 220 EX260 Integrated-type (For Output) Serial Transmission System 10-SV Dimensions: Series 10-SV1000 for EX260 Integrated-type (For Output) Serial Transmission System Tie-rod base manifold: 10-SS5V1-W10S1D U D B C3, N1 C4

Current consumption in power supply voltage range 22.8 to 26.4 VDC 2.0 A or less, according to the solenoid valve station specification Solenoid valve power supply EX260-SMJ1/-SMJ3 PNP (negative common) / source Output type EX260-SMJ2/-SMJ4 NPN (positive common) / Sink EX260-SMJ1/-SMJ2 32 outputs Number of outputs EX260-SMJ3/-SMJ4 16 outputs Solenoid valve connecting specification Output

IODD file Process data sizes IODD file Vacuum manifold stations input output SMC-EX260-VIL1_4-ymmdd-IODD1.1 4 4 byte 2 byte SMC-EX260-VIL1_8-ymmdd-IODD1.1 8 5 byte 3 byte SMC-EX260-VIL1_12-ymmdd-IODD1.1 12 6 byte 4 byte SMC-EX260-VIL1_16-ymmdd-IODD1.1 16 7 byte 5 byte Note "ymmdd" represents the date IODD file was created, "y" is the year, "mm" is the month and "dd" is the date. 3.2.

-SMJ1/-SMJ3 /PNP() EX260-SMJ2/-SMJ4 /NPN() EX260-SMJ1/-SMJ2 32 EX260-SMJ3/-SMJ4 16 / DC24 V1.5 W SMC DC 0.4 V CC-Link Ver.1.10 1 164 I/O 156 kbps/625 kbps/2.5 Mbps/5 Mbps/10 Mbps Ver.2.00()Ver.1.10SI SY SY3000SY5000SY7000 VQC VQC1000VQC2000VQC4000VQC5000 SV SV1000SV2000SV3000(10 base) S0700 S0700 EX250 -26No.EX-OMP0004CN-I SI16 28 -27No.EX-OMP0004CN-I (BUS OUT) (1)(SPEEDCON

EtherNet/IPTM is a trademark of ODVA. 2012 SMC Corporation All Rights Reserved 3 EX260-SEN3 ex260_sen3_22_v**.eds 4 ex260_sen4_22_v**.eds EX260-SEN4

EDS file Product number File name Contents (EDS file and icon) 1 EX260-SEN2-X205 ex260_sen2_x205_24_v.zip ex260_sen2_x205_24_v.eds, ex260-sen2-x205.ico Setting using RSLogix5000TM The method of connecting the SI unit with a Rockwell Automation EtherNet/IPTM (master) module is shown below.

Otherwise malfunction can result, causing an accident. 1 EX260-SPN1/SPN2 GSDML-V.-SMC-EX260-.xml Tightening torque 0.6 Nm 2 EX260-SPN3/SPN4 : Thread size: M3 x 30 Output number assignment Output numbering starts at zero and refers to the solenoid position on the manifold. The following instructions must be followed during maintenance: Turn off the power supply.

XDD file Model number XDD file 1 EX260-SPL1 F0007_EX260-SPL1.xdd 2 EX260-SPL3 F0007_EX260-SPL3.xdd URL http://www.smcworld.com Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2018 SMC Corporation All Rights

<EX260-SEC1/-SEC2/-SEC3/-SEC4> Fieldbus interface connector layout 6 RUN L/A IN L/A OUT PWR(V) PWR BUS OUT: M12 4-pole Socket D-coded 1 No.

Display Instructions (1) < Rotary switch (EX260-SEN#, etc.) > Set the EtherNet/IPTM device to Remote control mode. Rotary switch: Set the IP address setting switches to 000. DIP switch: Set all switches to OFF.

How to import the IODD file of the SMC EX260-SIL1 is shown below. The IODD file can be downloaded from the URL below.

New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer