-SMJ4 EX260-SMJ3 32 EX260-SEC2 EX260-SEC1 EtherCAT M12 16 EX260-SEC4 EX260-SEC3 32 EX260-SPN2 EX260-SPN1 For details about the EX series (Serial transmission system), refer to Best Pneumatics No. 1-1 and the Operation Manual.

<EX260-SMJ1/-SMJ2/-SMJ3/-SMJ4> Switch setting The switches should only be set with the power supply turned off. Open the cover and set the rotary switches and DIP switch with a small flat blade screwdriver. Fieldbus interface connector layout 6 BUS OUT: M12 5-pin socket A-coded EX260 Series for CC-Link No.

SMJ3 /-SMJ5 > DG DG DG SLD SLD SLD CC-Link-dedicated cable FG CC-Link-dedicated cable 5 FG FG DIP SW.1 DIP SW.2 ON EX180 Series for CC-Link 6 1 Figure 2 PWR(V) PWR L ERR 0 1 2 3 4 5 6 7 8 9 10 1 2 1 Thank you for purchasing an SMC EX180 Series Fieldbus device (Hereinafter referred to as "SI unit").

SI Unit (Safety Communication) EX260 PS1 F Series Part no.

P/E port entry on one side or Top ported Plug wEX260 SI unit EX260 Note) It can be selected only if no symbol or S or V or B is selected for the pilot and the piping.

9, @0 EX260 EX123/124/126 EX500 EX600 EX245 EX250 EX120/121/122 EX140 EX180 EX510 M8/M12 ATEX @1, @2, @4, @5 Type 1 Type 2 Type 3 Type 1 Type 2 @6, @7 @1 to @3 EX260 EX250 p. 233 p. 235 @6 to #0 @6, @9 VProduct Table Series Protocols No. Part no. Connector type Cable length EtherNet/IP End plate EX600-ED2m !

<EX260-SPR1/-SPR2/-SPR3/-SPR4> Fieldbus interface connector layout GSD file <EX260-SPR1/-SPR2/-SPR3/-SPR4> 7 Part number GSD file BUS OUT: M12 5-pole Socket B-coded 1 EX260 Series for PROFIBUS DP 1 EX260-SPR1/-SPR2 Smc_1430.gsd No.

Refer to the SMC website or the SV series in the Best Pneumatics No. 1 for details on solenoid valve specifications, Common Precautions and Specific Product Precautions. 220 EX260 Integrated-type (For Output) Serial Transmission System 10-SV Dimensions: Series 10-SV1000 for EX260 Integrated-type (For Output) Serial Transmission System Tie-rod base manifold: 10-SS5V1-W10S1D U D B C3, N1 C4

EtherNet/IPTM is a trademark of ODVA. 2012 SMC Corporation All Rights Reserved 3 EX260-SEN3 ex260_sen3_22_v**.eds 4 ex260_sen4_22_v**.eds EX260-SEN4

EDS file Product number File name Contents (EDS file and icon) 1 EX260-SEN2-X205 ex260_sen2_x205_24_v.zip ex260_sen2_x205_24_v.eds, ex260-sen2-x205.ico Setting using RSLogix5000TM The method of connecting the SI unit with a Rockwell Automation EtherNet/IPTM (master) module is shown below.

Otherwise malfunction can result, causing an accident. 1 EX260-SPN1/SPN2 GSDML-V.-SMC-EX260-.xml Tightening torque 0.6 Nm 2 EX260-SPN3/SPN4 : Thread size: M3 x 30 Output number assignment Output numbering starts at zero and refers to the solenoid position on the manifold. The following instructions must be followed during maintenance: Turn off the power supply.

XDD file Model number XDD file 1 EX260-SPL1 F0007_EX260-SPL1.xdd 2 EX260-SPL3 F0007_EX260-SPL3.xdd URL http://www.smcworld.com Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2018 SMC Corporation All Rights

<EX260-SEC1/-SEC2/-SEC3/-SEC4> Fieldbus interface connector layout 6 RUN L/A IN L/A OUT PWR(V) PWR BUS OUT: M12 4-pole Socket D-coded 1 No.

Display Instructions (1) < Rotary switch (EX260-SEN#, etc.) > Set the EtherNet/IPTM device to Remote control mode. Rotary switch: Set the IP address setting switches to 000. DIP switch: Set all switches to OFF.

How to import the IODD file of the SMC EX260-SIL1 is shown below. The IODD file can be downloaded from the URL below.

<EX260-SDN1/-SDN2/-SDN3/-SDN4> Bit: 7 0 Byte 0 Offset Fieldbus interface connector layout 16 outputs type 6 0: Solenoid valve: OFF 1: Solenoid valve: ON Bit: 7 0 Byte 1 Offset BUS OUT: M12 5-pole Socket A-coded 32 outputs type EX260 Series for DeviceNetTM BUS IN: M12 5-pole Plug A-coded Bit: 7 0 Byte 2 Offset Contact layout Bit: 7 0 No.