SMC Corporation of America
Elite Part Number Search
Search Results "D-M9NL-50"

Example) XLA-25H0-2M9NJLA-XAN1A 18 XLm Series Dimensions XLA/F (With D-M9mJm) C E E C E Fn D Heat-resistant auto switch H B A Heater G A [mm] Series Valve size A B C D E Fn G H 25 50 121 48 27 12 40 26 44 40 65 171 66 39 11 55 41 67 50 70 185 79 46 11 75 52 72 XLA XLF XLC/G25, 40 (With D-M9mJm) XLC/G50 (With D-M9mJm) C E C E E C E E C E Fn B A Fn D D Heat-resistant auto switch H J K H B A

(D)UKC32 Rc 1 8 Rc 1 8 14 18 26 32 40 50 3 4 8 10 9 10 8 10 16 20 20 22 33 43.5 33.5 34 12 5 to 50 19 21.5 15.5 5 to 50 Model H J L P Q QA R S SA T Y Z MM ZC(D)UKC16 ZC(D)UKC20 ZC(D)UKC25 ZC(D)UKC32 ( ): In the case of a mounted auto switch.

Power/Voltage At the Rated Voltage Model Starting Power (W) Current (A) Power (W) Current (A) Holding G/C/D/T, P5G 1.5 36 4.8 14.8 10 4.9 2.3 5.3 20 13.5 6.7 3.0 0.38 0.35 0.27 0.11 0.10 0.5 0.46 0.36 0.15 0.12 50 Hz 60 Hz 50 Hz 60 Hz P1G 0.47 30.5 XLS-16P2G 0.24 30 G/C/D/T, P5G 2.0 47 50 Hz 60 Hz 50 Hz 60 Hz P1G 0.62 42 XLS-25P2G 45 0.35 XLA Construction/Operation XL XL Internal control

D-Y7P D-Y69 D-Y7PV D-Y7W D-M9V D-F9WV D-Y7WV D-M9 D-F9BAL D-F9W Model MHS 4 8 1 6.5 3 1.5 Open Closed Open Closed Open Closed Open Closed MHZJ2-10 With dust cover No setting No setting MHC MHZJ2-16 No setting No setting MHT MHZJ2-20 MHY MHZJ2-25 MHW Note) There is no auto switch protrusion from the body's end surface.

2 L MRHQ 0 10 20 30 40 50 60 0 50 100 150 Misc.

Flange size XMD Symbol Nil D C Type KF (NW) K (DN) CF Applicable flange size 25, 40, 50, 63, 80 63, 80 40 (070), 63 (114) XYD V V V V V XMD V V V V V Size 25 40 50 63 80 XYD Nil D KF (NW) K (DN) 25, 40, 50, 63, 80 63, 80 3.

Angle type In-line type q w e r t y u w Flange type q Flange size XMA Type KF (NW) K (DN) CF Symbol Nil D C XMA XYA Applicable flange size 16, 25, 40, 50, 63, 80 63, 80 16 (034), 40 (070), 63 (114) Size 16 25 40 50 63 80 XYA Nil D K (DN) KF (NW) 25, 40, 50, 63, 80 63, 80 e Indicator/Pilot port direction XMA Rear flange surface XYA Symbol Rear flange surface Right flange surface Indicator

Size: 10 to 200 B A Magnet Operating range at proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch Lm Reed switch Solid state switch D-M9 D-M9V, D-F9W, D-F9WV, D-F9BAL D-A9, D-A9V Rotation Size Operating angle m Operating angle m Operating angle m Hysteresis angle A Hysteresis angle Hysteresis angle A B B B A 10 10 10 10 10 10 10 90 80 65 50 45

Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 118"(3m)) Internal resistance D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.

Same side Same side Different sides Different sides D-C7/C80 50 50 + 45 (n 2) 10 15 15 + 45 ( n 2) (n = 2, 4, 6) 2 D-H7/H7W D-H7NF 60 + 45 (n 2) 60 15 10 15 + 50 ( n 2) (n = 2, 4, 6) Mounting D-C73C/C80C D-H7C D-B5 D-B64 D-G5NTL 2 65 + 50 (n 2) 65 15 10 Warning 15 + 50 ( n 2) (n = 2, 4, 6) 15 75 2 10 1. Do not rotate the cover.

(mm) Proper tightening torque (Nm) Cylinder stroke (mm) Model 5 10 15 20 25 30 40 50 6, 10 16 20, 25 32 M3 M4 M5 M6 1.08 10% 2.45 10% 5.10 10% 8.04 10% 22 (27) 25 (35) 28 (38) 31 (41) 34 (44) 37 (47) C(D)U6-D 36 (41) 40 (50) 44 (54) 48 (58) 52 (62) 56 (66) C(D)U10-D 50 (75) 56 (86) 62 (92) 68 (98) 74 (104) 80 (110) C(D)U16-D 95 (128) 106 (143) 117 (154) 128 (165) 139 (176) 150 (187)

Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Electrical entry (Fetching direction) 2-color Indication Solid State Switch D-F9BW(V), D-F9NW(V), D-F9PW(V) 2-color Indication Solid State Switch D-F9BW(V), D-F9NW(V), D-F9PW(V) (mm) Type Model Features Grommet (In-line) D-A90 Stroke (mm) 20 41 29 47 35 Without indicator light Stroke (mm) 10

MDHR3-15 MDHR3-10 H L H When auto switch D-M9V is used When auto switch D-M9 is used When auto switch D-M9V is used Max. Protrusion of Auto Switch from Edge of Body: L, H Max. Protrusion of Auto Switch from Edge of Body: H (mm) (mm) D-M9V D-M9V D-M9N Auto switch model Auto switch model L H 1.3 The auto switch will not protrude in the case of D-F9. H 2.3 12-5-26

Without auto switch (Without built-in magnet) Remarks Symbol Heater Temperature 16 D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Nil H0 H4 H5 5 to 60C None None With 100C heater With 120C heater Solid state auto switch 5 to 150C Reed auto switch (Not applicable to flange size 16) Note) Size 16 is not

35 + 25 (n 2) (n = 2, 3, 4, 5) CJ2 D-A9lV 5 10 35 10 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 25 (n 2) (n = 2, 3, 4, 5) CM2 Band mounting CG1 D-H7l/H7lW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) MB D-C7l D-C80 10 15 50 15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) CA2 D-H7C D-C73C D-C80C 10 15 65 15 + 50(n 2)

Solid State Switch: D-M9B, D-M9N, D-M9P, D-F9BW, D-F9NW, D-F9PW Stroke B Stroke E Model A 10 20 30 40 75 100 125 150 10 20 30 125 40 50 150 75 100 50 B MXQ6 0.5 0.5 0.5 7.5 7.5 9.5 9.5 9.5 17.5 17.5 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MXQ8 26 2 2 6

Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch mounting

Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch

Mounting Bolt for C55 Model C D Mounting bolt Model C D Mounting bolt Model C D Mounting bolt C(D)55B20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B50-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B63-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B32-5 -

M9 M9V F9W(V) B Electrical entry is in the direction C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV D-M9 D-F9W D-M9V D-F9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C