Magnetically Coupled Rodless Cylinder/Slider Type: Ball Bushing Bearing Series CY1L Replacement Procedure is 6, 10, 15, 20 25, 32, 40 P.318 Construction Slider type, ball bushing bearing CY1L6 $0 #9 #8 $1 CY1L10 to 40 #9 $0 $2 #8 $0 #7 $1 F G G unit (10) 10,15 Enlarged view F $1 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CY1L. *BLUE links will lead
0.40 CY1L32L 0.40 18.2 CY1S CY1L40H 0.65 47.0 40 CY1L40L 0.40 29.0 2.
0.40 CY1L32L 0.40 18.2 CY1L40H 0.65 47.0 40 CY1L40L 0.40 29.0 2.
Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1.
0.40 29.0 40 CY1L40L 0.40 Note) Use caution, as there is a possibility of breaking the magnetic coupling if operated above the maximum operating pressure. 2) Intermediate stopping of load with an air pressure circuit When stopping a load using an air pressure circuit, operate at or below the kinetic energy shown in the table below.
29.0 0.40 40 CY1L40L 0.40 Note) Use caution, since the magnetic coupling may be dislocated if it is used over the maximum operating pressure. 2.
29.0 0.40 40 CY1L40L 0.40 Note) Use caution, since the magnetic coupling may be dislocated if it is used over the maximum operating pressure. 2.
Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.
circuit With diagnostic output (2-color indication) 4-wire (NPN) 5 V, 12 V IC circuit 3-wire (NPN equivalent) A76H 5 V Yes Grommet A72H A73H A80H A72 A73 A80 A73C A80C 200 V 100 V 100 V or less 12 V Relay, PLC 2-wire IC circuit No Yes 5 V, 12 V 12 V 24 V IC circuit No Connector 5 V, 12 V Lead wire length symbols: 0.5 m Nil (Example) J79W 3 m L (Example) J79WL 5 m Z (Example) J79WZ
Bore Size: 40mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 400mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Bore Size: 40mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 400mm, Adjuster: B [Shock Absorbers (2 pcs)], Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 40, Stroke(mm): 400, Max. Load Mass (Horizontal Mounting)(kg): 40~57, Table Size Length L(mm): 136, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Rolling Guide] Ball bushing bearing, Table Size Width W(mm): 187, Table Size Height H(mm): 76, Table Surface Treatment: [Anodize] Alumite, Environment
Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail
Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.
Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail
Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail
(Example) J79W (Example) J79WL (Example) J79WZ (Example) J79CN Solid state auto switches marked with are produced upon receipt of order. Lead wire length symbols: 0.5 m Nil 3 m L 5 m Z None N Sincethereareotherapplicableautoswitchesthanlisted,refertopage1520fordetails. Fordetailsaboutautoswitcheswithpre-wiredconnector,refertopages1648and1649.