There were no hits with the full part number, but there were 4 hits in the keyword search.
There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
Magnetically Coupled Rodless Cylinder/Slider Type: Ball Bushing Bearing Series CY1L Replacement Procedure is 6, 10, 15, 20 25, 32, 40 P.318 Construction Slider type, ball bushing bearing CY1L6 $0 #9 #8 $1 CY1L10 to 40 #9 $0 $2 #8 $0 #7 $1 F G G unit (10) 10,15 Enlarged view F $1 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CY1L. *BLUE links will lead
Bore Size: 32mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Bore Size: 32mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs.
Bore Size: 32mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 3 pcs.
Type: Magnetic, Guide: [Rolling Guide] Ball bushing bearing, Table Size Width W(mm): 157, Table Size Height H(mm): 64, Table Surface Treatment: [Anodize] Alumite, Environment: General Purpose, Maximum Load(kg): 30, Types: Magnetic retention force H type, Port Screw Type: Rc, Adjuster Option: Shock absorbers included (2 pcs.), Switch Rail: Yes, Specification: Magnet built-in, Auto Switches: A73
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, LE, 32MM CY1H/CY1L DBL-ACT A/S, 15.54258 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)32CY1L32H30.00.65
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
Auto Switches/Proper Mounting Position for Stroke End Detection B A (mm) Dimension A Dimension B Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-F7W/J79W D-F7WV D-F7LF Note 2) D-F7W/J79W D-F7WV D-F7LF Note 2) D-A73/A80 D-A73/A80 D-F7NTL D-F7NTL D-F79F D-F7BAL D-F79F D-F7BAL Bore size (mm) 6 23 23.5 45 44.5 27.5 40.5
30.0 0.65 32 CY1L32H 0.65 CY1L32L 18.2 0.40 32 CY1L32L 0.40 CY1L40H 47.0 0.65 40 CY1L40H 0.65 CY1L40L 29.0 0.40 40 CY1L40L 0.40 Note) Use caution, since the magnetic coupling may be dislocated if it is used over the maximum operating pressure. 2.
0.65 CY1L25H 0.65 18.5 32 25 CY1L32L 0.40 CY1L25L 0.40 11.2 CY3B CY3R CY1L40H 0.65 CY1L32H 0.65 30.0 40 32 CY1L40L 0.40 CY1L32L 0.40 18.2 CY1S CY1L40H 0.65 47.0 40 CY1L40L 0.40 29.0 2.
0.65 CY1L25H 0.65 18.5 32 25 CY1L32L 0.40 CY1L25L 0.40 11.2 CY1L40H 0.65 CY1L32H 0.65 30.0 40 32 CY1L40L 0.40 CY1L32L 0.40 18.2 CY1L40H 0.65 47.0 40 CY1L40L 0.40 29.0 2.
Reed auto switch Solid state auto switch 2-wire 12 V Connector Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V 24 V 2-wire Grommet Water resistant (2-color indicator) 12 V F7BA F7BAV With diagnostic output (2-color indicator) IC circuit F79F 4-wire (NPN) 5 V, 12 V 3-wire (NPN equivalent) IC circuit A76H 5 V A72H A73H A80H A72 A73
)] Stroke 4 [2] 2 [4] (142) [Origin] Note 4) Origin Note 3) 65 6.5 30 79 Motor cable (2 x 5) 60 46.8 Motor option: With lock Step motor Servo motor 7.5 M4 x 0.7 thread depth 8 (F.G. terminal) Cable length y 250 (194) 65 15 15 20 20 24 20 5H9 depth 5 ( ) 0.030 0 24 20 Lock cable (3.5) n x 5.5 [mm] 6 Model L 582 634 682 734 782 834 882 934 982 1034 1082 1134 A B n D E LEFS32;-300 LEFS32;-300B
When an analog output unit or analog input unit is connected to Slot 0, and channel 0 needs to be changed to analog range 4-20mA. 3) Select Channel0 (Sub Index 01) from the Slot _AnalogRange (Index 300B) folder.
Note No intermediate bracket is attached to IZS30-300B (SB), IZS30-780B (SB)). Intermediate bracket A. Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.
Please contact us for the latest version.sales@ocaire.com, CL1TF140-300B, ACTUATOR, CL1 TIE-ROD CYLINDER, UD, 140MM CL1 DOUBLE-ACTING, .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CLLocked-up cylinderCL1Double acting, Single rodApplicable to ?125 to 160999