SMC Corporation of America
Elite Part Number Search
Search Results "CY1L25H-600B-J79"

Magnetically Coupled Rodless Cylinder/Slider Type: Ball Bushing Bearing Series CY1L Replacement Procedure is 6, 10, 15, 20 25, 32, 40 P.318 Construction Slider type, ball bushing bearing CY1L6 $0 #9 #8 $1 CY1L10 to 40 #9 $0 $2 #8 $0 #7 $1 F G G unit (10) 10,15 Enlarged view F $1 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series CY1L. *BLUE links will lead

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 600, Max. Load Mass (Horizontal Mounting)(kg): 20~39.9, Table Size Length L(mm): 86, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Rolling Guide] Ball bushing bearing, Table Size Width W(mm): 127, Table Size Height H(mm): 52, Table Surface Treatment: [Anodize] Alumite, Environment

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

-X 20Data Weight Auto Switch Internal Circuit D-F79 (g) D-F79 D-F7P D-J79 Auto switch model DC (+) Brown 13 11 13 0.5 Lead wire length (m) 57 50 57 3 Main circuit of switch Main circuit of switch OUT Black 92 81 92 5 DC () Blue Dimensions 3.5 mounting hole D-F7P Indicator light DC (+) Brown OUT Black DC () Blue D-J79 Most sensitive position OUT (+) Brown Main circuit of switch OUT () Blue

Auto Switches/Proper Mounting Position for Stroke End Detection B A (mm) Dimension A Dimension B Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-F7W/J79W D-F7WV D-F7LF Note 2) D-F7W/J79W D-F7WV D-F7LF Note 2) D-A73/A80 D-A73/A80 D-F7NTL D-F7NTL D-F79F D-F7BAL D-F79F D-F7BAL Bore size (mm) 6 23 23.5 45 44.5 27.5 40.5

18.5 0.65 25 CY1L25H 0.65 CY1L25L 11.2 0.40 25 CY1L25L 0.40 CY1L32H 30.0 0.65 32 CY1L32H 0.65 CY1L32L 18.2 0.40 32 CY1L32L 0.40 CY1L40H 47.0 0.65 40 CY1L40H 0.65 CY1L40L 29.0 0.40 40 CY1L40L 0.40 Note) Use caution, since the magnetic coupling may be dislocated if it is used over the maximum operating pressure. 2.

0.40 7.0 CY1L32H 0.65 CY1L25H 0.65 18.5 32 25 CY1L32L 0.40 CY1L25L 0.40 11.2 CY3B CY3R CY1L40H 0.65 CY1L32H 0.65 30.0 40 32 CY1L40L 0.40 CY1L32L 0.40 18.2 CY1S CY1L40H 0.65 47.0 40 CY1L40L 0.40 29.0 2.

0.40 7.0 CY1L32H 0.65 CY1L25H 0.65 18.5 32 25 CY1L32L 0.40 CY1L25L 0.40 11.2 CY1L40H 0.65 CY1L32H 0.65 30.0 40 32 CY1L40L 0.40 CY1L32L 0.40 18.2 CY1L40H 0.65 47.0 40 CY1L40L 0.40 29.0 2.

250 65 M4 x 0.7 thread depth 8 (F.G. terminal) 15 15 20 20 20 24 ( ) 3H9 depth 3 0.025 0 20 Lock cable (3.5) 24 n x 4.5 4 48 [mm] Model L 335.5 380.5 435.5 480.5 535.5 580.5 635.5 680.5 735.5 780.5 835.5 880.5 A B n D E 120 D x 120 (= E) B 10 LEFS25;-100 LEFS25;-100B LEFS25;-200 LEFS25;-200B LEFS25;-300 LEFS25;-300B LEFS25;-400 LEFS25;-400B LEFS25;-500 LEFS25;-500B LEFS25;-600 LEFS25;-600B

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs))

Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 600, Max. Load Mass (Horizontal Mounting)(kg): 20~39.9, Table Size Length L(mm): 86, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Rolling Guide] Ball bushing bearing, Table Size Width W(mm): 127, Table Size Height H(mm): 52, Table Surface Treatment: [Anodize] Alumite, Environment

Change holding force of magnet (for example, CY1L25L CY1L25H) is carried out in our plant. To ask for this, please contact with our sales office. 2-6. Expected use under present of water (warmed water), coolant and so on, is advised to consult with us. Fig. 1-(a) Correct direction Fig. 1-(b) Incorrect direction Fig. 1 Direction of the slider 1-5.

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A72--Reed, AC Volt.<200, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 600mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: L (3m)