Guide Suffix: 1 Axis, Bore Size: 20mm, Port Thread: Rc, Stroke: 400mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: Y59B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -

Guide Suffix: 1 Axis, Bore Size: 20mm, Port Thread: Rc, Stroke: 400mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: Y69A--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: -, Number: -

Guide Suffix: 1 Axis, Bore Size: 20mm, Port Thread: Rc, Stroke: 400mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -

Y69B 3 m L Y69BL 5 m Z Y69BZ IC circuit 2-wire Y59B Y69B Solid state switch 12 V Relay PLC Grommet 24 V Yes 3-wire (NPN) 3-wire (PNP) Solid state auto switches marked with a are manufactured upon receipt of order. Y7NW Y7NWV 5 V 12 V Diagnostic indication (2 color indication) IC circuit Y7PW Y7PWV Refer to page 8-30-1 for detailed auto switch specifications.

each holding point 0.5m L 3m D Double Acting A C T I O N T Y P E O F A U T O S W I T C H E S See Accessories Section S T R O K E Model Bore Size(mm) 10 16 20 25 32 40 MHL2-D 20 30 40 50 70 100 MHL2-D1 40 60 80 100 120 160 MHL2-D2 60 80 100 120 160 200 1 2 ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Auto Switch Number D-Y59AL D-Y69AL D-Y59BL D-Y69BL

Standard Type 1 Right Angle Type S Y M B O L S ACCESSORIES AUTOSWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Auto Swith No D-Y59AL D-Y69AL D-Y59BL D-Y69BL Lead Wire Entry In-line Perpendicular In-line Perpendicular Wiring Method 3 wire NPN 2 wire Application PLC 24VDC PLC Power Source 5, 12, 24VDC Current Consumption 1mA or less

D-Y59BL 2 pcs. 25 15 D-Y69BL 1 pcs. D-Y7PL Solid state switch CJ1 Auto switches are mounted on the same side but in different grooves of the cylinder.

D-Y59BL 2 pcs. 25 15 D-Y69BL 1 pcs. D-Y7PL Solid state switch CJ1 Auto switches are mounted on the same side but in different grooves of the cylinder.

Lead wire length symbols: 0.5 mNil(Example) Y69B 3 m L (Example) Y69BL 5 m Z (Example) Y69BZ 8-25-8 8 Non-rotating Double Power Cylinder Series MGZ Specifications 32 50 25 20 63 80 40 Bore size (mm) Action Double acting, Single rod Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Standard stroke: 0.08 MPa Min. operating pressure Long stroke: 0.12 MPa MX Without auto switch

Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail

Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.

Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail

Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail

L Y69BL 5m . Z Y69BZ Note 2) Solid state switches marked with a "" symbol are produced upon receipt of order. Switch spacer Note 3) When later installing auto switches on a cylinder ordered without auto switches, the switch spacers in the table below are necessary. Switch spacers Applicable bore size (mm) Switch spacer 40, 50, 63 BMP1-032 Mounting bracket part nos.

Y69B Y59B 12V 2-wire 3-wire (NPN) Relay, PLC REC Grommet Y7NWV Y7NW Yes 24V IC circuit Diagnostic indication (2-color indication) 5V, 12V Y7PWV Y7PW 3-wire (PNP) CX Y7BWV Y7BW 12V 2-wire Water resistance (2-color indication) Y7BA CY Lead wire length symbols: Solid state switches marked with a "" symbol are produced upon receipt of order. 0.5 mNil 3 m L 5 m Z (Example) Y69B (Example) Y69BL

IC circuit 3-wire (NPN) Y59A Y69A 5V 12V 12V 5V 12V IC circuit 3-wire (PNP) Y7PV Y7P 2-wire Y59B Y69B Relay, PLC Solid state switch Y7NWV Y7PWV Y7BWV Y7NW Y7PW Y7BW Y7BA 3-wire (NPN) 3-wire (PNP) 24V Yes Grommet Diagnostic indication (2 color indication) IC circuit 12V 2-wire Water resistant (2 color indication) Lead wire length symbols: 0.5 m Nil (Example) Y69B 3 m L (Example) Y69BL