There were no hits with the full part number, but there were 27 hits in the keyword search.
There were no hits with the full part number, but there were 8 hits in the keyword search.
Product Information » New Products Search Results
Pressure Control Equipment Industrial Filters CXSL6 @3 @2 @4 CXSL10 CXSL15 @3 @4 @2 @3 @2 @4 CXSL20 to 32 @3 @2 @4 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series CXS. *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) Seal Kit List Description Material Note No.
Y7NW Y7NWV 5 V 12 V Diagnostic indication (2 color indication) IC circuit Y7PW Y7PWV Refer to page 8-30-1 for detailed auto switch specifications.
switch model Lead wire length (m) Load voltage Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 3 (L) 5 (Z) 0.5 (Nil) Perpendicular In-line 3-wire IC circuit Reed switch Solid state switch Z76 5 V Grommet (NPN equivalent) Yes Yes 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW Relay, PLC 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV
Seal kits consist of items 19 through 21, and can be ordered by using the seal kit number corresponding to each bore size. 13 Series CXS Construction: Ball Bushing Bearing CXSL6 CXSL10 CXSL15 CXSL20 to 32 Parts list Parts list: Standard piping Description Material Synthetic resin Note 2) Note No. 18 19 20 21 22 23 24 25 26 27 28 29 Description Material Aluminum alloy Special steel Special
DC AC Perpendicular In-line 3 wire Z76 5V IC circuit Yes Relay, PLC Reed switch Z73 Grommet 100V 12V 24V 2 wire 5V, 12V 100V or less Z80 IC circuit No 3 wire (NPN) 3 wire (PNP) Y69A Y59A 5V, 12V IC circuit Y7PV Y7P 2 wire Y69B Y59B 12V Solid state switch Relay, PLC 24V 3 wire (NPN) 3 wire (PNP) Y7NWV Y7NW Yes Grommet 5V, 12V Diagnostic indication (2 color indicator) IC circuit Y7PWV
Auto switch model Lead wire length (m) 0.5 (Nil) 3 (L) 5 (Z) Load voltage Pre-wired connector Special function Type Indicator light Wiring (Output) Electrical entry Applicable load In-line AC Perpendicular DC Y59A Y7P Y59B Y7NW Y7PW Y7BW Y7BA Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 3-wire (NPN) 5 V, 12 V IC circuit 3-wire (PNP) Reed auto switch Solid state auto switch 12 V 2-wire Relay, PLC
E R A L L O A D W Auto Switch Model No Special Function Electrical Wiring Lead voltage Electrical Entry Direction Entry (Output) Type Indicator Perpendicular Inline DC AC D-Z76 3 Wire 5V Available Reed D-Z73 Grommet 100V Switch D-Z80 2 Wire Not 24V 5V 100V Newtons Available 12V or less D-Y69A D-Y59A 3 Wire NPN 5V D-Y69B D-Y59B 2 Wire 12V Solid D-Y7NWV D-Y7NW 3 Wire NPN 24V 12V State D-Y7PWV
For example, the CXSL20-100 and the CXSL20-100-Y7BW have the same dimensions. If 2 D-Y7BW auto switches are added to a CXSL20-100, it becomes a CXSL20-100-Y7BW.
-2 VV3Z3-40R-1 Gasket VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Manifold base Applicable base Sub-plate VV3Z3-40-2 VV3Z3-40-1 VV3Z3-40R-2 VV3Z3-40R-1 VT Applicable base VV3Z3-20-1 VV3Z3-21R-1 Manifold base VP Manifold base Part no.: DXT200-8-6A Round head
-2 VV3Z3-40R-1 Gasket VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Manifold base Applicable base Sub-plate VV3Z3-40-2 VV3Z3-40-1 VV3Z3-40R-2 VV3Z3-40R-1 VT Applicable base VV3Z3-20-1 VV3Z3-21R-1 Manifold base VP Manifold base Part no.: DXT200-8-6A Round head
SX3 LOZ 40R Type of actuation Rated voltage Common specifications Manual override Nil Positive common Negative common 2 position single solenoid 2 position double solenoid 3 position closed center 3 position exhaust center 3 position pressure center Indicate it with the following stations table.
Type SS3YJ5-40R-01 1/8 1/8 1/8 1/8 1/8 Base mounted for external pilot Type SS3YJ5-41R-M5 M5 x 0.8 1/8 SYJ54R Type SS3YJ5-41R-01 Type SS3YJ5-41R-C4 C4 C6 Type SS3YJ5-41R-C6 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base
Type SS3YJ5-40R-01 1/8 1/8 1/8 1/8 1/8 Base mounted for external pilot Type SS3YJ5-41R-M5 M5 x 0.8 1/8 SYJ54R Type SS3YJ5-41R-01 Type SS3YJ5-41R-C4 C4 C6 Type SS3YJ5-41R-C6 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base
(For manifold type 20, 21R) 1 SYJ5 2 5 M M5 Body ported SYJ5 4 5 M 01 1 Base mounted Thread type Port size Manual override 3 port F Nil Rc Nil: Without sub-plate 01: 1/8 port With sub-plate Nil: Non-locking push type G N T NPT NPTF Coil specifications Nil Standard With power saving circuit (24, 12 VDC only) T For sub-plate style, manifold type 40, 40R, 41, 41R Power saving circuit is not
Bore Size: Ø20, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 40mm
Bore Size: Ø20, Thread Type: Bore 6-20: M Thread; Bore 25-32: Rc, Stroke: 40mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Type SS3YJ5-40R-01 1/8 1/8 1/8 1/8 1/8 Base mounted for external pilot Type SS3YJ5-41R-M5 M5 x 0.8 1/8 SYJ54R Type SS3YJ5-41R-01 Type SS3YJ5-41R-C4 C4 C6 Type SS3YJ5-41R-C6 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base