Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With shock absorber (1 pc.), Operating Pressure(MPa): 0.10 to 1.0, Specification: Without magnet, Port
Cylinder: None, Model: N (Non-lube), Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 75mm, Cushion: B (Shock Absorbers, 2 pcs), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With shock absorber (1 pc.), Operating Pressure(MPa): 0.10 to 1.0, Specification: Without magnet, Port
CX2 slide units offer highly accurate positioning and smooth operation with large forces. Its compact design and low profile accommodate minimum space requirements to meet many design applications. CX2 units are available in three bore sizes and strokes from 1" to 8". Through- holes in the housing provide for direct load mounting or fixed positioning of the body. Optional auto-switches may
Contents Model CX2N10 CX2N15 CX2N25 CX2N10-PS CX2N15-PS CX2N25-PS @0 @1 22 @3 Rod seal Set of left nos. @0, @1, @3 22 is a non-replaceable part, so it is not included in the seal kit. Piston seal NBR Piston gasket Seal kit includes @0, @1, @3. Order the seal kit, based on each bore size. (The piston gasket @2 is not replaceable.)
-225 CX2N25-250 CX2N25-275 CX2N25-300 108.5 266 20.5 90 575 252 307 559 603 121 291 20.5 90 625 277 332 609 653 133.5 316 20.5 90 675 302 357 659 703 (mm) CXWM series: 16, 25 F 92.5 L 238 K 18.5 P 90 Q 514 S 227 SS 275 Z 502 ZZ 538 Model CXWM16-225 CXWM16-250 CXWM16-275 CXWM16-300 105 263 18.5 90 564 252 300 552 588 117.5 288 18.5 90 614 277 325 602 638 313 18.5 90 664 302 350 652 688 130
Contents Model CX2N10-PS CX2N15-PS CX2N25-PS CX2N10 CX2N15 CX2N25 CX2N10-PS CX2N15-PS CX2N25-PS @0 @1 22 @3 Rod seal Set of left nos. @0, @1, @3 22 is a non-replaceable part, so it is not included in the seal kit. Piston seal NBR Piston gasket Seal kit includes @0, @1, @3. Order the seal kit, based on each bore size. (The piston gasket @2 is not replaceable.)
Applicable body size Product name 2B to 37B, 150 to 650 Drain guide Drain cock AM-SA003 AM-SA004 75B, 850 Ball valve set 2) The auto-drain can be replaced alone on sizes 75B and 850. However, auto-drain replacement requires dedicated tools.
T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.
T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.
Applicable body size Product name 2B to 37B, 150 to 650 Drain guide Drain cock AM-SA003 AM-SA004 75B, 850 Ball valve set 2) The auto-drain can be replaced alone on sizes 75B and 850. However, auto-drain replacement requires dedicated tools.
T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.
T-slot B dimension T-slot A dimension T-slot B 27.5 4H9 D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Cross section C-C LXSH2BD-50B LXSH2BD-75B LXSH2BD-100B LXSH2BD-125B LXSH2BD-150B Refer to page 301 for mounting.
(Flange material: Carbon steel) Specifications Specifications AFF2B to 75B Applicable model AFF11B to 75B Applicable model Refer to How to Order for standard specifications on page 14-20-10. Refer to How to Order for standard specifications on page 14-20-10.
Bracket*1 Symbol 37B 75B 37 kW 75 kW Nil B *1 Bracket is included, (but not assembled).
, 650 75B, 850 Nil B C D BC BD Nil B D BD Nil B D BD 2B, 150 to 22B, 550 37B, 650 Refer to the "Air Preparation Equipment" portion of Best Pneumatics No. 3 for selecting the model number and size of a mist separator, etc. 75B, 850 : Applicable (Combinations other than those indicated are not possible.) 82 &RXUWHV\RI6WHYHQ(QJLQHHULQJ,QF5\DQ:D\6RXWK6DQ)UDQFLVFR&$ *HQHUDO Sensors/Measuring Instruments
300mm) Photo micro sensor wire (300mm) Brake wire (300mm) 4.5 4H9 +0.030 0 Brake electrical circuit +24V Brown [Yellow] 4H9 +0.030 0 3 6 0V 49 38 White [Yellow] Section C detail (Scale: 2/1) Stroke + 104 (Stroke: 50 to 100mm) Stroke + 121 (Stroke: 125 to 200mm) 4H9 +0.030 0 depth 6 E Note) A contact protection circuit is required when connecting a brake. 12 D E Model LXPB5BC-50B LXPB5BC-75B
For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.
For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.
Inlet pressure (MPa) 14-20-9 2 Series AFF How to Order AFF2B to AFF75B AFF 8B 03 J B Option Body size J Drain guide B female thread R IN-OUT reversal direction T Element service indicator 1 4 2B 4B 8B 11B 22B 37B 75B Standard 1 8 Standard 1 4 Standard 3 8 Standard 1 2 Standard 3 4 Accessory (Option) Symbol Description Bracket Nil B 1 Standard 11 2 Standard N.C. auto-drain C N.O. auto-drain