Bore size Series CM Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm Average speed (mm/s) System 20 25 32 40 40 50 63 80 100 125 140 160 VK 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ A VF 0 VFR 800 700 600 500 400 300 200 100
Dryer A G F E D C B B 7kVA IDF120D 360 30 11 300 260 400 540 IDF-TR7000-8 94 Three phase compound 9kVA IDF150D 400 40 13 350 300 450 650 IDF-TR9000-8 109 220, 240, 380, 400, 415, 440V (50/60Hz) 200V (50/60Hz) 11kVA IDF190D 550 60 13 400 350 600 450 IDF-TR11000-8 131 4-F A 13kVA IDF240D 400 60 13 350 300 450 600 IDF-TR13000-8 138 D 18kVA IDF370B 400 40 13 350 300 450 650 IDF-TR18000-8 179
150 Nil C D Nil H L S 300 300 75 Auto-drains listed on page 95 are attached.
When the external regenerative resistors for power are used at the rated load ratio, the resistor temperature increases to between 200 C and 300 C. The resistors must be used at or below the rated values. Check with the manufacturer for the resistors load characteristics.
(communication error) 100 ms 100 ms 100 ms 300 ms *Time-out 300 ms 300 ms 300 ms Message Message Message Message PC or PLC...etc Controller side (master station) EOT EOT EOT Servo side (slave station) 14 9 14.
310 0E 642 1E 300 0F 600 1F 290 PB18 LPF Low-pass filter setting Set the low-pass filter.
PB49]4(_ _ _ 1) _ _ x x 5.4 00h _ x _ _ 0:-40dB 1:-14dB 2:-8dB 3:-4dB 0h x _ _ _ 0h 5.4 [Hz] [Hz] 00 10 562 01 11 529 02 4500 12 500 03 3000 13 473 04 2250 14 450 05 1800 15 428 06 1500 16 409 07 1285 17 391 08 1125 18 375 09 1000 19 360 0A 900 1A 346 0B 818 1B 333 0C 750 1C 321 0D 692 1D 310 0E 642 1E 300 0F 600 1F 290 PB18 LPF 3141 100 [rad/s] 18000 [Pr. PB23] [Pr.
With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire D: With connector LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector H: Lead wire length 600 mm Type LN, MN: with 2 sockets.
location, P/R port with One-touch fitting for 6 VZ1000-3A-1D r VZ1000-3A-1U t SUP/EXH block assembly VZ1000-2A-1M y Note) Block pin (2 pcs.) is attached for q, e, t, y.
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
Bore size CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] Series 40 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQ4100--03 VQ4101--03 1100 1000 900 800 700 600 500 400 300 200 100 0 VQ5100--04 VQ5101--04 Values at extension
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
Grommet (G), (H) VZ3 20-M5 G H 3 4 5 VZ3420 VK Manual override (Non-locking) VZ3520 VZ (Lead wire length) (Mounting hole for manifold) VF G: 300 mm H: 600 mm VFR VP4 VZS VFS VS4 (Mounting hole) VQ7 2-M5 x 0.8 (PE port) EVS VFN (Piping port) L plug connector (L) VZ3 20-L-M5 M plug connector (M) VZ3 20-M-M5 3 4 5 3 4 5 300 (Lead wire length) 300 (Lead wire length) : With light/surge voltage
C6: T0604 C8: T0806 Applicable cable O.D. 3.5 to 7 3-3-57 Series VZ5000 2 Position Double VZ5220 Grommet (G), (H) VZ5220-01 G H Manual override (Non-locking) (Mounting hole for manifold) (Lead wire length) G: 300 mm H: 600 mm (Mounting hole) (PE port) (Piping port) L plug connector (L) VZ5220-L-01 M plug connector (M) VZ5220-M-01 (Lead wire length) 300 (Lead wire length) 300 : With light
12 218 200 13 234 216 14 250 232 15 266 248 16 282 264 17 298 280 18 314 296 19 330 312 M plug connector (M) Built-in speed controllers L plug connector (L) DIN terminal (D) MAX. 10 MAX. 11 Applicable cable O.D. 3.5 to 7 300 (Lead wire length) (Lead wire length) 300 : With light/surge voltage suppressor 3-3-44 5 Port Solenoid Valve Base Mounted Series VZ3000 Type 41 Manifold: Side Ported
mm H: 600 mm VFS (Lead wire length) VS4 VQ7 EVS VFN (mm) Stations L1 L2 15 306 294 14 287 275 13 268 256 12 249 237 11 230 218 10 211 199 9 192 180 8 173 161 7 154 142 6 135 123 5 116 104 4 97 85 3 78 66 2 59 47 L plug connector (L) DIN terminal (D) M plug connector (M) Built-in One-touch fittings MAX. 10 300 (Lead wire length) C6: MAX. 6 C8: MAX. 6.5 300 (Lead wire length) 2n-One-touch
) WWw(n+1D) Unit No.9 RWr(n+1E) WWw(n+1E) Channel diagnosis RWr(n+1F) WWw(n+1F) n: Start address -44No.EX-OMW1003-A Word area (2) Input register Slave -> Master Output register Master -> Slave Corresponding Unit No.
Disconnect and remove all cabling which enters the limit switch housing (300). Remove screws (325), 3 pcs. and lift out the limit switch base plate (324) complete with switches, LUI and connector block. Open screw (326) and turn the limit switch housing (300) from the positioner housing. Remove the electronics cover (39). Proceed with the valve controller as applicable.
For Air 1.0 Downstream pressure of valve (P2) [MPa] Upstream pressure of valve P1z1.0 MPa 0.8 Subsonic 0.9 0.6 Critical pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 3/64 (1.2) 50 100 150 3/32 (2.4) 100 200 300 400 1/8 (3.2) 300 200 100 400 500 600 700 5/32 (4) 200 1, 000 800 400 600 7/32 (5.6) Series VXN2 250 500 7/32 (5.6) Series VXN3 500 1, 000 1, 500 2, 000 Flow rate Q [L/min